32-5038-10
Numbers in [brackets] are for 50 Hz international systems.
5
User’s Information
Fig. 3
Rotate Latches
Before removing the door from the unit, remove the power
cable plug from the socket located in the corner of the door.
Power cable connection
▲
CAUTION
!
Handle the door only by using the handles on the
front of the door. Grasp the door by the handles as
depicted in Figure 3 to remove and replace the door.
Do not handle the door on the edges. Metal edges
may be sharp and could result in injury if the door is
not handled properly.
CLEANING
Cleaning Instructions:
The air cleaner utilizes a PRE-FILTER and
COLLECTION CELLS. The purpose of the PRE-FILTER
is to capture large particles before they enter the
COLLECTION CELLS which allows the COLLECTION
CELLS to work more efficiently.
1. Turn the air conditioning system off at the Comfort
Control (thermostat).
▲
WARNING
!
High Voltage is present within the air cleaner for
operation. Before removing the Power Door, turn
the power off and wait at least 15 seconds to allow
voltage to discharge. Failure to follow instructions
could result in death or serious personal injury.
2. Turn off power to the air cleaner by pushing and
holding the POWER button for three seconds. The
LED’s will remain on until the voltage has dis-
charged and it is safe to remove the door. This re-
quires approximately 15 seconds.
Do not remove
the door until all the lights are off.
3. Disconnect the power/control cable.
4. Rotate the two latches and remove the door as
shown in Figure 3. Place the door in a secure loca-
tion.
5. Remove the PRE-FILTER (Figure 4) and/or the
COLLECTION CELLS (Figure 5) from the air
cleaner.
Fig. 4
Fig. 5