20
CDHF-SVX01N-EN
Table 6. Rigging arrangements
Type
NTON
EVSZ
CDSZ
X
Y
H
in.
cm
ft
m
in.
cm
CDHF
1500–2000
210D
210D
117
297.18
22
6.7056
24.75
62.865
CDHF
2100–2500
250D
250D
117
297.18
22
6.7056
CDHF
2170–2550
250D
250D
143
363.22
23
7.0104
CDHG
1250–1750
210D
210D
117
297.18
22
6.7056
CDHG
2150
210D
210D
117
297.18
22
6.7056
CDHG
2150
250D
250D
117
297.18
22
6.7056
CDHG
2250
210D
210D
143
363.22
23
7.0104
CDHG
2250
250D
250D
143
363.22
23
7.0104
CDHF
3000
250M
250M
142
360.68
26.5
8.0772
CDHF
3500
250X
250X
164
416.56
30.5
9.2964
Notes:
1
.
Lifting chains (or cables) are not the same length between point A and B, or between points A and C. Adjust as necessary for an even lift.
2
.
Lifting holes provided on chillers to attach chains are 2-1/2 in. (63.5 mm) in diameter.
3
.
Attach safety chain (or cable) as shown, and without tension. The safety chain is not used for lifting, but is there to prevent the unit from rolling.
4
.
Do NOT fork-lift the unit.
Special Lift Requirements
N
NO
OT
TIIC
CE
E
O
Oiill L
Lo
ossss!!
F
Fa
aiillu
urre
e tto
o p
prre
ev
ve
en
ntt o
oiill m
miig
grra
attiio
on
n o
ou
utt o
off tth
he
e o
oiill tta
an
nkk
cco
ou
ulld
d rre
essu
ulltt iin
n e
eq
qu
uiip
pm
me
en
ntt ffa
aiillu
urre
e o
orr p
prro
op
pe
errtty
y--o
on
nlly
y
d
da
am
ma
ag
ge
e..
T
To
o p
prre
ev
ve
en
ntt o
oiill m
miig
grra
attiio
on
n o
ou
utt o
off tth
he
e o
oiill tta
an
nkk d
du
urriin
ng
g
lliiffttiin
ng
g p
prro
occe
ed
du
urre
ess,, rre
em
mo
ov
ve
e tth
he
e o
oiill ffrro
om
m tth
he
e o
oiill tta
an
nkk
iiff tth
he
e u
un
niitt w
wiillll b
be
e lliifftte
ed
d a
att a
an
ny
y a
an
ng
glle
e g
grre
ea
atte
err tth
ha
an
n
1
15
5°° ffrro
om
m h
ho
orriizzo
on
ntta
all e
en
nd
d--tto
o--e
en
nd
d.. IIff o
oiill iiss a
allllo
ow
we
ed
d tto
o
rru
un
n o
ou
utt o
off tth
he
e o
oiill tta
an
nkk iin
ntto
o o
otth
he
err a
arre
ea
ass o
off tth
he
e
cch
hiilllle
err,, iitt w
wiillll b
be
e e
ex
xttrre
em
me
elly
y d
diiffffiiccu
ulltt tto
o rre
ettu
urrn
n tth
he
e o
oiill
tto
o tth
he
e o
oiill tta
an
nkk e
ev
ve
en
n d
du
urriin
ng
g o
op
pe
erra
attiio
on
n..
N
NO
OT
TIIC
CE
E
E
Eq
qu
uiip
pm
me
en
ntt D
Da
am
ma
ag
ge
e!!
M
Mo
ov
viin
ng
g tth
he
e cch
hiilllle
err u
ussiin
ng
g a
a ffo
orrkk lliifftt cco
ou
ulld
d rre
essu
ulltt iin
n
e
eq
qu
uiip
pm
me
en
ntt o
orr p
prro
op
pe
errtty
y--o
on
nlly
y d
da
am
ma
ag
ge
e..
D
Do
o n
no
ott u
usse
e a
a ffo
orrkk lliifftt tto
o m
mo
ov
ve
e tth
he
e cch
hiilllle
err!!
N
NO
OT
TIIC
CE
E
C
Co
om
mp
prre
esssso
orr A
Alliig
gn
nm
me
en
ntt!!
F
Fa
aiillu
urre
e tto
o p
prre
esse
errv
ve
e cco
om
mp
prre
esssso
orr a
alliig
gn
nm
me
en
ntt cco
ou
ulld
d
rre
essu
ulltt iin
n e
eq
qu
uiip
pm
me
en
ntt o
orr p
prro
op
pe
errtty
y--o
on
nlly
y d
da
am
ma
ag
ge
e..
L
Liiffttiin
ng
g tth
he
e cco
om
mp
prre
esssso
orr//m
mo
otto
orr a
asssse
em
mb
blly
y ffrro
om
m tth
he
e
ssh
he
ellllss w
wiitth
ho
ou
utt ffa
acctto
orry
y--iin
nsstta
alllle
ed
d d
do
ow
we
elliin
ng
g iin
n tth
he
e
cco
om
mp
prre
esssso
orr cca
assttiin
ng
g fflla
an
ng
ge
ess cco
ou
ulld
d rre
essu
ulltt iin
n
m
miissa
alliig
gn
nm
me
en
ntt o
off tth
he
e cco
om
mp
prre
esssso
orr cca
assttiin
ng
gss..
If the chiller cannot be moved using a standard chiller
lift, consider the following:
•
When job site conditions require rigging of the
chiller at an angle greater than 45° from horizontal
(end-to-end), the unit may require removal of the
compressor. Contact Trane or an agent of Trane
specifically authorized to perform start-up and
warranty of Trane® products regarding the
disassembly and reassembly work. For more
information, refer to
.
N
No
otte
e:: Disassembly and reassembly work includes
dowel-pinning the compressor and removing
it from the unit. Contact Trane or an agent of
Trane specifically authorized to perform start-
up and warranty of Trane® products for
specific rigging instructions. Do NOT attempt
to rotate the chiller onto its side.
•
When lifting the chiller is either impractical or
undesirable, attach cables or chains to the jacking
slots shown in the figure in
; then push or pull the unit across a
smooth surface. Should the chiller be on a shipping
skid, it is not necessary to remove the skid from the
chiller before moving it into place.
•
If removal of the compressor or economizer
assembly is necessary to move the chiller to the
operating location, contact Trane. Also refer to
“Factory Warranty Information,” p. 3
Unit Isolation
To minimize sound and vibration transmission through
the building structure and to ensure proper weight
distribution over the mounting surface, always install
isolation pads or spring isolators under the chiller feet.