
3
Table of Contents
Section One
Section Two
Model Number Description .............................................. 4
Unit Nameplate ................................................................ 4
Hazard Identification ........................................................ 4
Unit Description ................................................................ 4
Unit Component Layout and "Shipwith" Locations .......... 5
Section Three
Unit Inspection ................................................................. 6
Unit Clearances ............................................................... 6
Unit Dimensions & Weight Information ............................ 6
Foundation ....................................................................... 6
Rigging ........................................................................... 14
Unit Isolation .................................................................. 15
Neoprene Isolators ..................................................... 15
Spring Isolators .......................................................... 16
Leveling the Unit ............................................................ 16
General Unit Requirements ........................................... 17
Refrigerant Piping .......................................................... 18
Discharge (Hot Gas) Lines ......................................... 18
Discharge Line Components ...................................... 19
Making Refrigerant Connections ................................... 19
Brazing Procedures ....................................................... 19
Leak Testing Procedure ................................................. 20
Field Installed Power Wiring .......................................... 20
Main Unit Power Wiring .............................................. 20
Field Installed Control Wiring ..................................... 23
CCAD Package Chiller Interface ................................ 23
Section Four
System Evacuation Procedures ..................................... 26
Voltage Imbalance ......................................................... 28
Electrical Phasing .......................................................... 28
Section Five
Sequence of Operation .................................................. 29
Verifying Proper Condenser Fan Rotation ..................... 30
Section Six
Monthly Maintenance ..................................................... 38
Coil Cleaning .................................................................. 39
Index .................................................................................. 40
Summary of Contents for CAUC-C20
Page 8: ...8 Figure 3 2 CAUC C20 Unit Dimensional Data Recommended Clearances...
Page 9: ...9 Figure 3 2 Continued CAUC C25 Unit Dimensional Data Recommended Clearances...
Page 10: ...10 Figure 3 2 Continued CAUC C30 Unit Dimensional Data Recommended Clearances...
Page 11: ...11 Figure 3 2 Continued CAUC C40 Unit Dimensional Data Recommended Clearances...
Page 12: ...12 Figure 3 2 Continued CAUC C50 Unit Dimensional Data Recommended Clearances...
Page 13: ...13 Figure 3 2 Continued CAUC C60 Unit Dimensional Data Recommended Clearances...
Page 24: ...24 Figure 3 7 Typical Interface Connection Diagram for CCAD 20 through 60 Ton Package Chiller...
Page 25: ...25...
Page 33: ...33 Blank...
Page 34: ...34 Figure 5 2 Typical Wiring Schematic for 20 through 60 Ton Units...
Page 35: ...35...
Page 36: ...36 Figure 5 3 Typical Control Panel Connections Diagram for 20 through 60 Ton Units...
Page 37: ...37...
Page 42: ...42...
Page 43: ...43...
Page 44: ...44...