background image

General Information

6

 ACC-SVN67M-EN

BAYHTRA436

TSC120H4, TSC092H4

TSC102H4

THC074F4, TZC072F4

WSC090H4

(a)

THC092F4, TZC090F4

WSC102H4

(a)

THC102F4, TZC102F4

WSC120H4

WSC092H4

(a)

WHC074H4, 
WHC092H4, 

WHC102H4

BAYHTRA454

TSC120H4

WSC120H4

BAYHTRZ454A

TZC120H4

BAYHTRAW18

TSC120HW

TSC102HQW

 TZC072FW, TSC092HW, 

WSC090HW

(a)

 THC092FW, TZC090FW

WSC102HW

(a)

THC102FW, TZC102FW

WSC120HW

WSC092HW

(a)

WHC074HW, 
WHC092HW, 

WHC102HW

BAYHTRAW27

WSC090HW

(a)

WSC102HW

(a)

WSC120HW

WSC092HW

(a)

WHC074HW, 
WHC092HW, 

WHC102HW

BAYHTRAW36

TSC120HW, TSC092HW, 

TSC102HW

TZC072FW

WSC090HW

(a)

THC092FW, TZC090FW

WSC102HW

(a)

THC102FW, TZC102FW

WSC120HW

WSC092HW

(a)

WHC074HW, 
WHC092HW, 

WHC102HW

BAYHTRAW54

TSC120HW

WSC120HW

BAYHTRB318

WHC120H3

BAYHTRB327

WHC120H3

BAYHTRB336

WHC120H3

BAYHTRB354

WHC120H3

BAYHTRB418

WHC120H4

BAYHTRB427

WHC120H4

BAYHTRB436

WHC120H4

BAYHTRB454

WHC120H4

BAYHTRBW18

TZC120FW

WHC120HW

BAYHTRBW36

WHC120HW

BAYHTRBW54

WHC120HW

BAYHTRD318

THC120E3

TZC120F3

BAYHTRD327

THC120E3

TZC120F3

BAYHTRD336

THC120E3

BAYHTRZ337A

TZC120F3

BAYHTRD354

THC120E3

BAYHTRZ354A

TZC120F3

BAYHTRD418

THC120E4

TZC120F4

BAYHTRD427

THC120E4

TZC120F4

BAYHTRD436

THC120E4

BAYHTRZ436A

TZC120F4

BAYHTRD454

THC120E4

BAYHTRZ454A

TZC120F4

BAYHTRU309

THC072F3

WSC090H3

WSC092H3

WSC102H3

BAYHTRU318

THC072F3

WSC090H3

WSC092H3

WSC102H3

BAYHTRU327

THC072F3

WSC090H3

WSC092H3

WSC102H3

BAYHTRU336

THC072F3

WSC090H3

WSC092H3

WSC102H3

BAYHTRU409

THC072F4

WSC090H4

WSC092H4

WSC102H4

BAYHTRU418

THC072F4

WSC090H4

WSC092H4

WSC102H4

BAYHTRU427

THC072F4

WSC090H4

WSC092H4

WSC102H4

BAYHTRU436

THC072F4

WSC090H4

WSC092H4

WSC102H4

BAYHTRUW18

THC072FW

WSC090HW

WSC092HW

WSC102HW

BAYHTRUW27

THC072FW

WSC090HW

WSC092HW

WSC102HW

BAYHTRUW36

THC072FW

WSC090HW

WSC092HW

WSC102HW

Table 1. Heater information (continued) 

Model Number

Used With

Summary of Contents for BAY24X042

Page 1: ...and requires specific knowledge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe...

Page 2: ...ous situation which if not avoided could result in minor or moderate injury It could also be used to alert against unsafe practices NOTICE Indicates a situation that could result in equipment or prope...

Page 3: ...ment are the trademarks of their respective owners Revision History Updated Heater Model Number for WSC120H3 in Electrical Data chapter WARNING Follow EHS Policies Failure to follow instructions below...

Page 4: ...4 ACC SVN67M EN Table of Contents General Information 5 General 7 Inspection 7 Installation 8 Electrical Data 12...

Page 5: ...H3 a WHC074H3 WHC092H3 WHC102H3 THC102F3 WSC120H3 BAYHTRA327 TSC120H3 WSC090H3 a THC074F3 TZC072F3 WSC102H3 a WSC120H3 THC092F3 TZC090F3 THC102F3 TZC102F3 TSC092H3 TSC102H3 WSC092H3 a WHC074H3 WHC092H...

Page 6: ...HC120H4 BAYHTRB436 WHC120H4 BAYHTRB454 WHC120H4 BAYHTRBW18 TZC120FW WHC120HW BAYHTRBW36 WHC120HW BAYHTRBW54 WHC120HW BAYHTRD318 THC120E3 TZC120F3 BAYHTRD327 THC120E3 TZC120F3 BAYHTRD336 THC120E3 BAYHT...

Page 7: ...must be reported immediately and a claim made against the transportation company 3 Check the heater nameplate model number and compare with the electrical data tables Ensure that the available power s...

Page 8: ...the same as any in this table and the application is for horizontal airflow the limit control TCO A must be replaced with the extra limit control shipped with the heater Replace TCO A following the in...

Page 9: ...rt rod hanger The BAYHTRA BAYHTRB and BAYHTRD models will have a guide rod and a support bracket to help with the installation See Figure 5 Be very careful to avoid dragging the heater element on the...

Page 10: ...ush against center post and secure each door stop with 1 or 2 screws See zoom view in Figure 8 or Figure 9 14 Remove the wire nuts from W1 W2 and W3 15 For models with the control box in the outdoor s...

Page 11: ...with ohmmeter and verify that heater element terminals are electrically isolated from cabinet and ground infinite resistance On downflow units with or without duct work installed or horizontal units w...

Page 12: ...nimum allowable airflow for a TSC120EF TZC120F and THC120E with a 54 kW heater is 3400 cfm e The minimum allowable airflow for a WSC120 with a 54 kW heater is 4000 cfm Table 4 Unit wiring with electri...

Page 13: ...35 34 35 33 35 7 5 c TSC092H4 BAYHTRT427 BAYHTRA427 d 27 2 44 45 48 50 47 50 7 5 c TSC092H4 BAYHTRT436 BAYHTRA436 d 36 2 58 60 61 70 60 60 8 5 TSC102H4 BAYHTRT409 BAYHTRA409 d 9 1 21 25 23 25 22 25 8...

Page 14: ...er Model Number Heater kW Rating Control Stages Standard Indoor Fan Motor a Oversized Indoor fan Motor Optional EBM Fan Motor MCA Max Fuse Size or Max Circuit Breaker MCA MaxFuseSize or Max Circuit Br...

Page 15: ...1 34 40 35 40 34 40 8 5 WSC102H4 BAYHTRU418 BAYHTRA418 18 0 1 47 50 49 50 48 50 8 5 WSC102H4 BAYHTRU427 BAYHTRA427 27 0 2 61 70 62 70 61 70 8 5 WSC102H4 BAYHTRU436 BAYHTRA436 36 0 2 74 80 76 80 75 80...

Page 16: ...or Max Circuit Breaker MCA Max Fuse Size or Max Circuit Breaker 208 230 Volts Three Phase 6 WHC074H3 BAYHTRA309 6 8 9 0 1 66 69 70 70 6 WHC074H3 BAYHTRA318 13 5 18 0 1 89 96 90 100 6 WHC074H3 BAYHTRA...

Page 17: ...nnection high efficiency and eFlex 6 to 10 tons Standard Indoor Motor Oversized Indoor Motor Tons Unit Model Number Heater Model Number Heater kW Rating a Control Stages MCA Max Fuse Size or Max Circu...

Page 18: ...AYHTRA409 9 0 1 18 9 25 6 THC074F4 BAYHTRA418 18 0 1 32 5 35 6 THC074F4 BAYHTRA427 27 0 2 46 0 50 460 Volts Three Phase 6 THC074F4 BAYHTRA436 36 0 2 59 5 60 6 TZC072F4 BAYHTRA409A 9 1 10 8 26 6 TZC072...

Page 19: ...egrees C b Degrees F c 6 Ton 7 5 Ton 10 Ton 6 Ton 7 5 Ton 10 Ton kW Voltage Stages 4100 M3 H 5100 M3 H 6800 M3 H kW Voltage Stages 2400 cfm 3000 cfm 4000 cfm WSC072ED WSC090ED WSC120 ED WSC072ED WSC09...

Page 20: ...umCircuit Breaker TSC072ED BAYHTRS418 11 3 13 5 39 47 1 26 9 28 9 35 35 28 1 30 1 35 35 BAYHTRS427 16 9 20 2 58 69 2 37 5 40 5 40 45 38 8 41 8 40 45 BAYHTRS436 22 6 26 9 78 92 2 48 3 52 1 50 60 49 5 5...

Page 21: ...Notes ACC SVN67M EN 21...

Page 22: ...Notes 22 ACC SVN67M EN...

Page 23: ...Notes ACC SVN67M EN 23...

Page 24: ...cations without notice We are committed to using environmentally conscious print practices Trane and American Standard create comfortable energy efficient indoor environments for commercial and reside...

Reviews: