WSHP-PRC001-EN
81
Performance Data
300-Heating
(0.45 ESP)
Table P-51: GEV 300 Heating Performance
Performance data is tabulated for heating at 68 F DB entering air at ARI/ISO 13256-1 rated CFM.
For conditions other than what is tabulated, multipliers must be used to correct performance. See the fan correction factors Table for CFM
other than rated and the heating correction factors for variations in entering air temperature. Data shown in
bold
type is performance data
at ARI/ISO 13256-1 WLHP and GLHP water only conditions. Antifreeze correction factors may be found on page 108
.
RATED ESP (in. H20): 0.45
RATED GPM:
75.0
MINIMUM CFM:
8000
RATED CFM:
10000
MAXIMUM CFM:
12000
EWT
GPM
Htg Cap
Mbtuh
Absorb
Mbtuh
Power
kW
LWT
Feet
Head
PSID
Head
SCFM
ISO Cap
Mbtuh
ISO
Power
kW
ISO COP
25
37.5
198.3
119.9
20.51
18.6
4.8
2.07
10000
192.3
18.86
2.99
50.0
203.2
132.7
20.66
19.7
7.6
3.29
197.2
19.13
3.02
62.5
207.1
136.1
20.79
20.6
10.9
4.71
201.1
19.45
3.03
75.0
210.4
139.1
20.90
21.3
14.6
6.32
204.4
19.82
3.02
87.5
213.1
141.5
20.99
21.8
18.7
8.09
207.1
20.25
3.00
GLHP
32
37.5
216.9
144.8
21.12
24.3
4.8
2.07
10000
210.8
19.47
3.17
50.0
222.2
149.5
21.30
26.0
7.6
3.29
216.2
19.78
3.20
62.5
226.8
153.6
21.46
27.1
10.9
4.71
220.8
20.12
3.22
75.0
230.7
157
21.59
27.8
14.6
6.32
224.6
20.52
3.21
87.5
233.8
159.7
21.70
28.4
18.7
8.10
227.8
20.97
3.18
45
37.5
252.4
176.1
22.36
35.6
4.8
2.07
10000
246.4
20.71
3.49
50.0
259.4
182.2
22.61
37.7
7.6
3.29
253.4
21.08
3.52
62.5
267.0
188.9
22.87
39.0
10.9
4.71
260.9
21.54
3.55
75.0
272.0
193.3
23.06
39.8
14.6
6.32
266.0
21.98
3.55
87.5
274.6
195.6
23.15
40.5
18.7
8.10
268.6
22.41
3.51
55
37.5
281.3
201.5
23.38
44.3
4.8
2.07
10000
275.3
21.73
3.71
50.0
289.7
208.9
23.68
46.6
7.6
3.29
283.7
22.16
3.75
62.5
297.0
215.3
23.94
48.1
10.9
4.71
290.9
22.60
3.77
75.0
303.1
220.7
24.15
49.1
14.6
6.32
297.0
23.08
3.77
87.5
308.1
225.1
24.33
49.9
18.7
8.09
302.1
23.60
3.75
WLHP
68
37.5
320.7
236.1
24.78
55.4
4.8
2.07
10000
314.7
23.13
3.99
50.0
331.2
245.4
25.14
58.2
7.6
3.28
325.2
23.62
4.04
62.5
340.3
253.4
25.46
59.9
10.9
4.70
334.3
24.12
4.06
75.0
348.0
260.2
25.73
61.1
14.6
6.30
342.0
24.65
4.07
87.5
354.4
265.8
25.95
61.9
18.7
8.08
348.4
25.21
4.05
75
37.5
342.9
255.7
25.55
61.3
4.8
2.06
10000
336.9
23.90
4.13
50.0
354.6
266
25.96
64.3
7.6
3.28
348.6
24.43
4.18
62.5
364.8
275
26.31
66.2
10.8
4.69
358.8
24.97
4.21
75.0
373.4
282.6
26.60
67.4
14.5
6.29
367.4
25.53
4.22
87.5
380.5
288.9
26.85
68.4
18.6
8.07
374.5
26.11
4.20
86
37.5
378.8
287.4
26.79
70.6
4.8
2.06
10000
372.8
25.14
4.35
50.0
392.4
299.4
27.26
74.0
7.6
3.27
386.4
25.73
4.40
62.5
404.2
309.8
27.66
76.0
10.8
4.68
398.2
26.32
4.43
75.0
414.2
318.6
28.00
77.5
14.5
6.28
408.2
26.92
4.44
87.5
422.5
325.9
28.29
78.5
18.6
8.04
416.5
27.55
4.43
Table P52: 300 Correction Factor for Variation in Entering Air Temperature
Cooling
Entering
Air WB F
Cooling
Capacity
Cooling
Input
Watts
Sensible vs Entering Dry Bulb
Multipliers
Heating
Entering
Air DB F
Heating
Capacity
Heating
Input
Watts
65.6
70.6
75.6
80.6
85.6
49.4
0.942
0.988
0.991
1.053
1.116
1.180
1.244
53.0
1.031
0.912
56.3
0.943
0.988
0.806
1.015
1.118
1.181
1.245
58.0
1.021
0.939
60.3
0.944
0.988
0.634
0.842
1.051
1.182
1.246
63.0
1.010
0.968
63.2
0.960
0.992
0.506
0.716
0.924
1.134
1.247
68.0
1.000
1.000
66.2
1.000
1.000
0.583
0.793
1.000
1.211
73.0
0.991
1.034
72.1
1.098
1.020
0.529
0.739
0.949
78.0
0.982
1.070
77.1
1.182
1.035
0.511
0.722
83.0
0.973
1.108
Table P53: 300 Fan Correction Factors
Entering
SCFM
Cooling
Capacity
Sensible
Capacity
Cooling
Input
Watts
Heating
Capacity
Heating
Input
Watts
8000
0.969
0.894
0.994
0.990
1.043
9000
0.986
0.948
0.997
0.995
1.021
10000
1.000
1.000
1.000
1.000
1.000
11000
1.013
1.051
1.003
1.004
0.983
12000
1.024
1.100
1.005
1.008
0.970
Summary of Contents for Axiom GEH006
Page 107: ...WSHP PRC001 EN 107 Control Wiring Basic 24V 1 PH 208V 60HZ 1PH ...
Page 108: ...108 WSHP PRC001 EN Control Wiring Deluxe 24V 3 PH 208V 60HZ 3PH ...
Page 109: ...WSHP PRC001 EN 109 Control Wiring Tracer ZN510 1PH 208V 60HZ 1PH ...
Page 110: ...110 WSHP PRC001 EN Dimensional Data Tracer ZN524 3PH 460V 60HZ 3PH ...
Page 123: ...WSHP PRC001 EN 123 Dimensional Data Front Return Back Supply 12 1 2 15 Ton ...
Page 124: ...124 WSHP PRC001 EN Dimensional Data Back Return Front Supply 12 1 2 15 Ton ...
Page 125: ...WSHP PRC001 EN 125 Dimensional Data Front Return Top Supply 12 1 2 15 Ton ...
Page 126: ...126 WSHP PRC001 EN Dimensional Data Back Return Top Supply 12 1 2 15 Ton ...