WSHP-PRC001-EN
97
Performance Data
Fan Performance - 300
Table F11: GEV 300 - Front/Back Supply
(includes wet coil, no filter)
GEV 300 - Front/Back Supply
(includes wet coil, no filter)
with 11 x 15 blower wheel
Std
Airfow
Unit External Static Pressure inches W.G. ( Wet Coil, 3% Drive Loss Included & No Return Air Filter)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
CFM
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
8000
652
2.78
669
2.90
688
3.01
708
3.12
730
3.26
755
3.42
780
3.59
804
3.75
829
3.93
853
4.10
876
4.27
898
4.43
9000
729
3.93
745
4.06
760
4.18
777
4.31
795
4.44
814
4.58
836
4.75
859
4.95
881
5.14
903
5.33
925
5.52
946
5.71
10000
807
5.35
821
5.50
835
5.64
849
5.78
864
5.92
880
6.06
897
6.21
916
6.39
936
6.59
957
6.82
976
7.02
996
7.23
11000
885
7.09
898
7.25
910
7.41
923
7.56
936
7.72
950
7.87
965
8.02
980
8.18
996
8.37 1014 8.58 1032 8.81 1050 9.04
12000
963
9.17
975
9.35
987
9.52
998
9.69 1010 9.86 1022 10.02
1035 10.19 1048 10.36 1062 10.53 1076 10.72 1091 10.92
1107 11.16
Std
Airfow
Unit External Static Pressure inches W.G. ( Wet Coil, 3% Drive Loss Included & No Return Air Filter)
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.4
CFM
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
8000
921
4.61
944
4.80
967
4.99
990
5.21 1015 5.47
1048 5.94 1087 6.58 1122 7.19 1146 7.54 1167 7.82 1186 8.07 1205 8.31
9000
966
5.90
987
6.09 1008 6.29 1028 6.48 1047 6.67 1067 6.88 1087 7.11 1109 7.36
1130 7.62 1155 8.01 1187 8.61 1222 9.36
10000
1016 7.44 1035 7.65 1054 7.87 1073 8.08 1091 8.29 1110 8.52 1127 8.72 1146 8.94 1164 9.16 1182 9.40 1200 9.64 1219 9.91
11000
1069 9.28 1087 9.51 1105 9.74 1122 9.97 1140 10.21 1156 10.43 1174 10.67 1190 10.90 1208 11.15 1225 11.38 1240 11.60 1258 11.86
12000
1124 11.41 1141 11.67 1158 11.92 1175 12.18 1190 12.42 1207 12.67 1223 12.93 1239 13.18 1255 13.43 1271 13.70 1287 13.95 1302 14.20
Std
Airfow
Unit External Static Pressure inches W.G.
(Wet Coil, 3% Drive Loss Included & No
Return Air Filter)
2.5
2.6
2.7
Package A
Package F
CFM
RPM
BHP
RPM
BHP
RPM
BHP
8000
1222
8.52
1238
8.73
1255
8.94
Package B
9000
1254
10.05
1278
10.54
1299
10.89
10000
1238
10.18
1257
10.49
1279
10.90
Package C
11000
1274
12.10
1290
12.36
1306
12.60
12000
1318
14.47
1332
14.71
1347
14.96
Package D
Package E
Summary of Contents for Axiom GEH006
Page 107: ...WSHP PRC001 EN 107 Control Wiring Basic 24V 1 PH 208V 60HZ 1PH ...
Page 108: ...108 WSHP PRC001 EN Control Wiring Deluxe 24V 3 PH 208V 60HZ 3PH ...
Page 109: ...WSHP PRC001 EN 109 Control Wiring Tracer ZN510 1PH 208V 60HZ 1PH ...
Page 110: ...110 WSHP PRC001 EN Dimensional Data Tracer ZN524 3PH 460V 60HZ 3PH ...
Page 123: ...WSHP PRC001 EN 123 Dimensional Data Front Return Back Supply 12 1 2 15 Ton ...
Page 124: ...124 WSHP PRC001 EN Dimensional Data Back Return Front Supply 12 1 2 15 Ton ...
Page 125: ...WSHP PRC001 EN 125 Dimensional Data Front Return Top Supply 12 1 2 15 Ton ...
Page 126: ...126 WSHP PRC001 EN Dimensional Data Back Return Top Supply 12 1 2 15 Ton ...