WSHP-PRC001-EN
73
Performance Data
060-Heating
Table P36: GEH/GEV 060 Heating Performance
Performance data is tabulated for heating at 68 F DB entering air at ARI/ISO 13256-1 rated CFM.
For conditions other than what is tabulated, multipliers must be used to correct performance. See the fan correction factors Table for CFM
other than rated and the heating correction factors for variations in entering air temperature. Data shown in
bold
type is performance data
at ARI/ISO 13256-1 WLHP and GLHP water only conditions. Antifreeze correction factors may be found on page 108
.
RATED GPM:
14.5
MINIMUM CFM:
1520
RATED CFM:
1900
MAXIMUM CFM:
2280
EWT
GPM
Htg Cap
Mbtuh
Absorb
Mbtuh
Power
kW
LWT
Ft.
Hd.
CFM
ISO Cap
Mbtuh
ISO Pwr
kW
ISO
COP
25
9.4
40.7
26.1
4.28
19.5
9.6
1900
39.0
3.83
3.0
11.6
41.9
27.2
4.30
20.3
12.6
40.2
3.89
3.0
13.1
42.2
27.5
4.31
20.8
15.0
40.5
3.93
3.0
14.5
42.3
27.6
4.31
21.2
17.6
40.6
3.96
3.0
15.2
42.3
27.6
4.31
21.4
19.0
40.6
3.99
3.0
16.0
42.3
27.6
4.31
21.5
20.5
40.6
4.01
3.0
17.4
42.3
27.6
4.32
21.8
23.7
40.6
4.07
2.9
GLHP
32
9.4
45.2
30.3
4.36
25.6
8.9
1900
43.7
3.97
3.2
11.6
46.6
31.7
4.38
26.5
12.0
45.1
4.02
3.3
13.1
47.0
32.0
4.39
27.1
14.2
45.5
4.06
3.3
14.5
47.2
32.2
4.40
27.6
16.7
45.7
4.11
3.3
15.2
47.2
32.2
4.41
27.8
18.0
45.7
4.13
3.2
16.0
47.3
32.3
4.41
28.0
19.4
45.8
4.16
3.2
17.4
47.4
32.4
4.41
28.3
22.4
45.9
4.21
3.2
45
9.4
54.7
39.1
4.58
36.7
8.1
1900
53.0
4.12
3.8
11.6
56.1
40.4
4.61
38.0
11.0
54.4
4.18
3.8
13.1
56.6
40.8
4.62
38.7
13.0
54.9
4.22
3.8
14.5
56.9
41.1
4.63
39.3
15.3
55.2
4.26
3.8
15.2
57.1
41.3
4.64
39.6
16.6
55.4
4.29
3.8
16.0
57.2
41.4
4.64
39.8
17.8
55.5
4.31
3.8
17.4
57.5
41.6
4.65
40.2
20.6
55.8
4.37
3.7
55
9.4
62.2
45.9
4.78
45.3
7.5
1900
60.5
4.32
4.1
11.6
63.6
47.2
4.81
46.9
10.3
61.9
4.38
4.1
13.1
64.1
47.6
4.82
47.7
12.3
62.4
4.42
4.1
14.5
64.6
48.1
4.84
48.4
14.4
62.9
4.46
4.1
15.2
64.7
48.2
4.84
48.7
15.6
63.0
4.48
4.1
16.0
64.9
48.3
4.85
48.9
16.9
63.2
4.51
4.1
17.4
65.3
48.7
4.86
49.4
19.5
63.6
4.57
4.1
WLHP
68
9.4
71.6
54.4
5.04
56.4
6.9
1900
69.9
4.58
4.5
11.6
72.9
55.6
5.08
58.4
9.6
71.2
4.64
4.5
13.1
73.4
56.0
5.10
59.4
11.4
71.7
4.69
4.5
14.5
73.8
56.4
5.11
60.2
13.5
72.1
4.73
4.5
15.2
74.1
56.6
5.12
60.6
14.6
72.4
4.75
4.5
16.0
74.3
56.8
5.12
60.9
15.8
72.6
4.77
4.5
17.4
74.7
57.2
5.13
61.4
18.3
73.0
4.82
4.4
75
9.4
76.2
58.5
5.18
62.6
6.6
1900
74.5
4.71
4.6
11.6
77.3
59.5
5.21
64.7
9.2
75.6
4.77
4.6
13.1
77.8
60.0
5.23
65.8
11.1
76.1
4.82
4.6
14.5
78.2
60.3
5.25
66.7
13.1
76.5
4.86
4.6
15.2
78.5
60.6
5.25
67.0
14.2
76.8
4.88
4.6
16.0
78.7
60.7
5.26
67.4
15.3
77.0
4.91
4.6
17.4
79.2
61.2
5.27
67.9
17.8
77.5
4.96
4.6
86
9.4
82.1
63.8
5.36
72.4
6.2
1900
80.4
4.89
4.8
11.6
83.0
64.6
5.39
74.8
8.8
81.3
4.95
4.8
13.1
83.4
64.9
5.41
76.0
10.6
81.7
4.99
4.8
14.5
83.8
65.3
5.43
77.0
12.5
82.1
5.04
4.8
15.2
84.0
65.5
5.43
77.4
13.6
82.3
5.05
4.8
16.0
84.3
65.7
5.44
77.7
14.7
82.6
5.08
4.8
17.4
84.8
66.2
5.45
78.4
17.1
83.1
5.13
4.7
Table P37: 060 Fan Correction Factors
Entering
CFM
Cooling
Capacity
Sensible
Capacity
Cooling
Input
Watts
Heating
Capacity
Heating
Input
Watts
1520
0.974
0.892
0.965
0.972
1.032
1615
0.980
0.919
0.973
0.979
1.024
1710
0.987
0.945
0.981
0.986
1.016
1805
0.993
0.972
0.990
0.993
1.008
1900
1.000
1.000
1.000
1.000
1.000
2090
1.012
1.051
1.020
1.013
0.984
2185
1.019
1.078
1.030
1.020
0.976
2280
1.025
1.105
1.042
1.027
0.968
Summary of Contents for Axiom GEH006
Page 107: ...WSHP PRC001 EN 107 Control Wiring Basic 24V 1 PH 208V 60HZ 1PH ...
Page 108: ...108 WSHP PRC001 EN Control Wiring Deluxe 24V 3 PH 208V 60HZ 3PH ...
Page 109: ...WSHP PRC001 EN 109 Control Wiring Tracer ZN510 1PH 208V 60HZ 1PH ...
Page 110: ...110 WSHP PRC001 EN Dimensional Data Tracer ZN524 3PH 460V 60HZ 3PH ...
Page 123: ...WSHP PRC001 EN 123 Dimensional Data Front Return Back Supply 12 1 2 15 Ton ...
Page 124: ...124 WSHP PRC001 EN Dimensional Data Back Return Front Supply 12 1 2 15 Ton ...
Page 125: ...WSHP PRC001 EN 125 Dimensional Data Front Return Top Supply 12 1 2 15 Ton ...
Page 126: ...126 WSHP PRC001 EN Dimensional Data Back Return Top Supply 12 1 2 15 Ton ...