WSHP-SVX01Y-EN
7
GEV Models
Digits 1–3 — Unit Configuration
GEV
= Standard Efficiency Vertical
Digit 4 — Development Sequence
G
Digits 5–7 — Nominal Size (MBH)
006
= 6.0 MBH
009
= 9.0 MBH
012
= 12.0 MBH
015
= 15.0 MBH
018
= 18.0 MBH
024
= 24.0 MBH
030
= 30.0 MBH
036
= 36.0 MBH
042
= 42.0 MBH
048
= 48.0 MBH
060
= 60.0 MBH
Digit 8 — Voltage (Volts/Hz/Phase)
4
= 460/60/3
7
= 265/60/1
A
= 208-230/60/1
B
= 208-230/60/3
Digit 9 — Heat Exchanger
1
= Copper-Water Coil
2
= Cupro-Nickel Water Coil
7
= Insulated Copper-Water Coil/Suction Line
8
= Insulated Cupro-Nickel Water Coil/
Suction Line
Digit 10 — Design Sequence
A
First Design Sequence
Digit 11 — Refrigeration Circuit
0
= Heating and Cooling Circuit
2
= Heating and Cooling Circuit with Hot Gas
Reheat
3
= Heating and Cooling Circuit with
Waterside Economizer
4
= Heating and Cooling Circuit with
Waterside Economizer, Hot Gas Reheat
Digit 12 — Blower Configuration
K
= Variable ECM Motor, Constant Torque
Digit 13 — Freeze Protection
A
= 20°F Freezestat
B
= 35°F Freezestat
Digit 14 — Open Digit = 0
Digit 15 — Supply-Air Arrangement
T
= Top Supply-Air Arrangement
B
= Back Supply-Air Arrangement
Digit 16 — Return-Air Arrangement
L
= Left Return-Air Arrangement
R
= Right Return-Air Arrangement
Digit 17 — Control Types
B
= Tracer
®
ZN524 Controls
D
= Deluxe 24V Controls
H
= UC400/B
J
= UC400B w/Air-Fi
®
Wireless
Communications
Digit 18 — Tstat/Sensor Location
0
= Wall Mounted Location
Digit 19 — Fault Sensors
1
= Condensate Overflow Sensor
3
= Condensate Overflow and Filter
Maintenance Timer
6
= Condensate Overflow and Fan Status
J
= Fan Status, Filter Maintenance Timer and
Condensate Overflow Sensor
Digit 20 — Temperature Sensor
0
= No Additional Temperature Sensor
1
= Entering Water Sensor
Digit 21 — Insulation
1
= Matte Faced Insulation
2
= Foil Faced Insulation
Digit 22 — Electric Heat Option
0
= No Electric Heat
6
= Factory Mounted External Boilerless Low
Electric Heat
7
= Factory Mounted External Supplemental
Low Electric Heat
8
= Field Mounted External Boilerless Electric
Heat
9
= Field Mounted Supplemental Electric Heat
A
= Factory Mounted External Boilerless
Medium Electric Heat
B
= Factory Mounted External Supplemental
Medium Electric Heat
C
= Factory Mounted External Boilerless High
Electric Heat
D
= Factory Mounted External Supplemental
High Electric Heat
Digit 23 — Unit Mounted Disconnect
0
= No Unit Mounted Disconnect
2
= Unit Mounted Disconnect
Digit 24 — Filter Type
1
= 1-inch Throwaway Filter
2
= 2-inch Throwaway Filter
4
= 2-inch MERV 8
5
= 2-inch MERV 13
Digit 25 — Acoustic Arrangement
1
= Standard Sound Attenuation
2
= Deluxe Sound Attenuation
Digits 26–36 — Does Not Apply
00000000000
= Digits 26-36 are not
applicable to the GEH or GEV products
Digit 37 — Ducted Filter Rack
0
= Non-ducted filter rack
A
= Ducted Filter Rack (Side Access/LH—RH)
Digit 38 — Isolation Valve
0
= No Isolation Valve
1
= Factory Mounted Isolation Valve
Digit 39 — Power Connection
1
= Single Point
2
= Dual Point (Electric Heat Power Separate
from Unit)
Digit 40 — Drain Pan
A
= Polymer Drain Pan
B
= Stainless Steel Drain Pan
Model Number Note:
Note:
Back Supply, Electric Heat and Deluxe
Sound option are avalible in later
product release.