6
WSHP-SVX01Y-EN
Model Number Description
Digits 1–3 — Unit Configuration
GEH
= Standard Efficiency Horizontal 0.5 to
15 Tons
GEV
= Standard Efficiency Vertical 6 to 25
Tons
Digit 4 — Development Sequence
E
= R-410A
Digits 5–7 — Nominal Capacity
006
= 0.5 Tons
009
= 0.75 Tons
012
= 1 Tons
015
= 1.25 Tons
018
= 1.5 Tons
024
= 2 Tons
030
= 2.5 Tons
035
= 3 Tons
042
= 3.5 Tons
048
= 4 Tons
060
= 5 Tons
072
= 6 Tons
090
= 7.5 Tons
120
= 10 Tons
150
= 12.5 Tons
180
= 15 Tons
240
= 20 Tons
300
= 25 Tons
Digit 8 — Voltage (Volts/Hz/Phase)
0
= 115/60/1
1
= 208/60/1
2
= 230/60/1
3
= 208/60/3
4
= 460/60/3
5
= 575/60/3
6
= 220–240/50/1
7
= 265/60/1
8
= 230/60/3
9
= 380–415/50/3
Digit 9 — Heat Exchanger
1
= Copper-Water Coil
2
= Cupro-Nickel Water Coil
7
= Insulated Copper-Water Coil
8
= Insulated Cupro-Nickel Water Coil
Digit 10 — Current Design Sequence
Digit 11 — Refrigeration Circuit
0
= Heating and Cooling Circuit
2
= Heating and Cooling Circuit with Hot Gas
Reheat
3
= Heating and Cooling Circuit with
Waterside Economizer
4
= Heating and Cooling Circuit with HGR and
WSE
Digit 12 — Blower Configuration
1
= Standard Blower Motor
2
= High Static Blower Motor
A
= Drive Package A
B
= Drive Package B
C
= Drive Package C
D
= Drive Package D
E
= Drive Package E
F
= Drive Package F
G
= Drive Package G
H
= Drive Package H
J
= Drive Package J
1*
= 2 Speed Drive Package A
2*
= 2 Speed Drive Package B
3
= 2 Speed Drive Package C
4
= 2 Speed Drive Package D
5
= 2 Speed Drive Package E
6
= 2 Speed Drive Package F
7
= 2 Speed Drive Package G
8
= 2 Speed Drive Package H
9
= 2 Speed Drive Package J
Digit 13 — Freeze Protection
A
= 20°F Freezestat
B
= 35°F Freezestat
Digit 14 — Open Digit = 0
Digit 15 — Supply-Air Arrangement
B
= Back Supply-Air Arrangement
F
= Front Supply-Air Arrangement
L
= Left Supply-Air Arrangement
R
= Right Supply-Air Arrangement
T
= Top Supply-Air Arrangement
Digit 16 — Return-Air Arrangement
B
= Back Return-Air Arrangement
F
= Front Return-Air Arrangement
L
= Left Return-Air Arrangement
R
= Right Return-Air Arrangement
Digit 17 — Control Types
D
= Deluxe 24V Controls
B
= Tracer
®
ZN524 Controls
F
= UC400
G
= UC400 w/Wireless Comm
Digit 18 — Tstat/Sensor Location
0
= Wall Mounted Location
Digit 19 — Fault Sensors
1
= Condensate Overflow Sensor
3
= Condensate Overflow and Filter
Maintenance Timer
6
= Condensate Overflow and Fan Status
J
= Fan Status, Filter Maintenance Timer and
Condensate Overflow Sensor
Digit 20 — Temperature Sensor
0
= No Temperature Sensor
1
= Entering Water Sensor
Digit 21 — Insulation
1
= Standard Fiberglass Insulation
2
= Foil-faced Insulation in Airstream
Digit 22 — Electric Heat
0
= No Electric Heat
1
= Internal Boilerless Electric Heat
4
= External Boilerless Electric Heat
5
= External Supplemental Electric Heat
Digit 23 — ON/OFF Switch
0
= No
“ON”
/
“OFF”
Switch
1
=
“ON”
/
“OFF”
Switch
Digit 24 — Filter Type
1
= 1" Throwaway Filter
2
= 2" Throwaway Filter
4
= 2” MERV 8
5
= 2” MERV 13
Digit 25 — Acoustic Arrangement
0
= Enhanced Sound Attenuation
1
= Deluxe Sound Attenuation
Digits 26–36 — Does Not Apply to GEH
or GEV
00000000000
= Digits 26-36 are not
applicable to the GEH or GEV products
Digits 35 — Unit Drain Pan Option
A
= Polymer Drain Pan
B
= Stainless Steel Drain Pan
Model Number Notes
Notes:
1
.
0.5 to 1 Ton only
2
.
6 to 25 Tons only
3
.
0.5 to 5 Tons only
4
.
Extended Range Geothermal
5
.
Only available on vertical units
6
.
ON/OFF switch not available with
boilerless electric heat option or units
over 60 amps
7
.
0.5 to 5 Tons (horizontal only)