Unit Dimensions and Weights
18
WSHP-SVX01L-EN
Figure 11. Right return/right supply (GEH/EXH)
(a)
(a) When a horizontal model is ordered with right return with end discharge, filter access could be limited.
TOP
BACK
LEFT SIDE
FRONT
RI
G
HT SIDE
B
P
N
A
C
H
H
E
D
J
1" (25.4)
K
DRAIN
3/4" (1
9
) NPTI
BLOWER
ACCESS
PANEL
F X G
OPENING
REFRI
G
AND
CONTROL
ACCESS
HI VOLT
LO VOLT
14"
(356)
Q
L (W.O.)
M (W.I.)
R
S
1"
(25.4)
1 3/8" (35)
7" (1
78)
6 3/4" (1
71)
1/2"
(1
3)
Table 8.
Right return/right supply (GEH/EXH)
GEH Unit
A
B
C
D
(a)
E
F x G
H
J
K
L
NPTI
M
NPTI
N
P
Q
R
(b)
S
006, 009
40
(1016)
20
(508)
15
(381)
20
(508)
15
(381)
6-7/8 x 8
(175) x (203)
11-1/2
(292)
4-1/2
(114)
1-3/4
(45)
1/2
(13)
1/2
(13)
38-3/4
(984)
18-3/4
(476)
13-5/8
(346)
18-1/2
(470)
3-1/4
(83)
012, 015
40
(1016)
20
(508)
15
(381)
20
(508)
15
(381)
6-7/8 x 9-7/8
(175) x (251)
11-1/2
(292)
4-1/4
(108)
2-3/4
(70)
1/2
(13)
1/2
(13)
38-3/4
(984)
18-3/4
(476)
13-5/8
(346)
18-1/2
(470)
3-1/4
(83)
018
46
(1168)
23
(584)
18
(457)
23
(584)
18
(457)
8-1/4 x 9-3/4
(210) x (248)
13-1/2
(343)
4-3/4
(121)
3-1/4
(83)
3/4
(19)
3/4
(19)
44-3/4
(1137)
21-3/4
(552)
16-5/8
(422)
18-1/2
(470)
4-1/4
(108)
024, 030
46
(1168)
23
(584)
18
(457)
23
(584)
18
(457)
8-1/4 x 11-3/8
(210) x (289)
13-1/2
(343)
4-3/4
(121)
3-1/4
(83)
3/4
(19)
3/4
(19)
44-3/4
(1137)
21-3/4
(552)
16-5/8
(422)
18-1/2
(597)
4-1/4
(108)
036, 042
50
(1270)
25
(635)
19
(483)
25
(635)
20
(508)
10-1/2 x 13-1/2
(267) x (343)
17
(432) 4 (102)
1
(25)
3/4
(19)
3/4
(19)
48-3/4
(1238)
23-3/4
(603)
17-5/8
(448)
23-1/2
(597)
3-1/4
(83)
Std-048
58
(1473)
33
(838)
21
(533)
29-1/2
(597)
23-1/2
(749)
13-1/8 x 11-3/8
(333) x (289)
18
(457)
5-1/4
(133)
1-1/2
(38)
1
(25)
1
(25)
56-3/4
(1441)
31-3/4
(806)
19-5/8
(498)
23-1/2
(597)
5-1/2
(140)
Hi-048, 060
58
(1473)
33
(838)
21
(533)
29-1/2
(597)
23-1/2
(749)
13-7/8 x 13-7/8
(352) x (352)
18
(457)
5-1/4
(133)
1-1/2
(38)
1
(25)
1
(25)
56-3/4
(1441)
31-3/4
(806)
19-5/8
(498)
23-1/2
(597)
5-1/2
(140)
EXH Unit
A
B
C
D
(a)
E
F x G
H
J
K
L
NPTI
M
NPTI
N
P
Q
R
(b)
S
018, 024
46
(1168)
23
(584)
18
(457)
23
(584)
18
(457)
8-1/4 x 11-3/8
(210) x (289)
13-1/2
(343)
4-3/4
(121)
3-1/4
(83)
3/4
(19)
3/4
(19)
44-3/4
(1137)
21-3/4
(552)
16-5/8
(422)
18-1/2
(470)
4-1/4
(108)
030, 036
50
(1270)
25
(635)
19
(483)
25
(635)
20
(508)
10-1/2 x 13-1/2
(267) x (343)
17
(432)
4
(102)
1
(25)
3/4
(19)
3/4
(19)
48-3/4
(1238)
23-3/4
(603)
17-5/8
(448)
23-1/2
(597)
3-1/4
(83)
042-060
58
(1473)
33
(838)
21
(533)
29-1/2
(597)
23-1/2
(749)
13-1/8 x 11-3/8
(333) x (289)
18
(457)
5-1/4
(133)
1-1/2
(38)
1
(25)
1
(25)
56-3/4
(1441)
31-3/4
(806)
19-5/8
(498)
23-1/2
(597)
5-1/2
(140)
070
58
(1473)
39
(991)
21
(533)
29-1/2
(597)
23-1/2
(749)
13-7/8 x 13-7/8
(352) x (352)
18
(457)
5-1/4
(133)
1-1/2
(38)
1
(25)
1
(25)
56-3/4
(1441)
37-3/4
(959)
19-5/8
(498)
23-1/2
(597)
5-1/2
(140)
Notes:
1. All dimensions are in inches followed by millimeters in parenthesis.
2. Clearance must be 18 in. (457 mm) for access to service. NEC requires 36 in. on the control panel side of the unit. If supply or return are not located
on a long side of the unit, this side will not require more than a 2 in. (51 mm) clearance. Forklift is recommended when rigging the unit. GEH units
only: If hot gas reheat is specified for a size 018, 024, the actual cabinet size increases to an 036 cabinet.
(a) Return air opening dimension
(b) Filter rack dimension