7
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER (BTU/Watt-Hr.)
Sound Power Rating [dB(A)]
Performance Heating
(High Temp.)BTUH
Power Input (KW)
(Low Temp.) BTUH
Power Input (KW)
HSPF (BTU / Watt-Hr.)
POWER CONN.—V/Ph/Hz
Min. Brch. Cir. Ampacity
Fuse Size — Max. (amps)
Fuse Size — Recmd. (amps)
COMPRESSOR
Volts/Ph/Hz
R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT
Charge (lbs.)
DIMENSIONS
Crated (in.)
WEIGHT
Shipping (lbs.) / Net (lbs.)
4WCY4048A3000C
208-230/3/60
47000
1400
3.97
11.75 / 14.0
73
42500
3.56
27200
3.44
8.0
208-230/3/60
25.3
35
35
SCROLL
208-230/3/60
13.7 / 83
SPINE-FIN
2 / 24
18.01
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4440
1/4 / 825
230/1/60
1.4 / 3.37
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
NO
THROWAWAY
5.3
R410A
7.75
H X W X L
47.86 / 47.4 / 61.75
607 / 479
4WCY4060A3000C
208-230/3/60
58000
1780
4.95
11.5 / 14.0
76
55000
4.60
37600
4.29
8.0
208-230/3/60
28.6
45
45
SCROLL
208-230/3/60
16.0 / 110
SPINE-FIN
2 / 24
23.57
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
5700
1/3 / 830
230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
NO
THROWAWAY
5.3
R410A
10.125
H X W X L
51.86 / 47.4 / 61.75
623 / 495
1
Certified in accordance with the Unitary Air-Conditioner Equipment
certification program, which is based on AHRI Standard 210/240.
2
Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
3
Calculated in accordance with currently prevailing Nat'l Electrical Code.
4
Standard Air — Dry Coil — Outdoor.
5
Standard Air — Wet Coil — Indoor.
6
Rated in accordance with D.O.E. test procedure.
7
Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are
used size per manufacturer's recommendations with clean resistance of 0.05" W.C.
4WCY4060B1000C
208-230/1/60
58000
1785
4.95
12.0 / 14.0
76
55000
4.48
35400
4.30
8.0
208-230/1/60
39.9
60
60
SCROLL
208-230/1/60
25 / 134
SPINE-FIN
2 / 24
23.07
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
5700
1/3 / 830
230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
NO
THROWAWAY
5.3
R410A
11.94
H X W X L
51.86 / 47.4 / 61.75
623 / 495
Summary of Contents for 4WCY4024
Page 9: ...9 Single Power Entry Kit Data Table 2 BAYSPEK060F Ampacity and Max Fusing Circuit Breakers...
Page 10: ...10 Table 3 BAYSPEK061 Ampacity and Max Fusing Circuit Breakers Single Power Entry Kit Data...
Page 16: ...16 Typical Wiring...
Page 17: ...17 Typical Wiring...
Page 24: ...24 Dimensional Data and Weights 4WCY4024 through 4WCY4036 2 of 3...
Page 25: ...25 Dimensional Data and Weights 4WCY4024 through 4WCY4036 3 of 3...
Page 27: ...27 Dimensional Data and Weights 4WCY4042 through 4WCY4060 2 of 3...
Page 28: ...28 Dimensional Data and Weights 4WCY4042 through 4WCY4060 3 of 3...