Button and led status
With reference to the description on the previous page , this is a summary of the button
functionality and the corresponding led status, including alarm buzzer.
State
Description
Effect
Led
0
Nothing (off). The default
position of any button.
Outputs associated with
this key will be turned off.
Green and red led off.
1
A normal press on a key
(< 5 seconds).
Not confirmed.
The output module will
receive a message to turn
on the respective (main)
output.
Rapid green flash.
2
A long press on a key (> 5
seconds).
Not confirmed.
The output module will
receive a message to turn
on the respective (spare)
output.
Rapid green flash, each
4
th
blink is dark.
3
Main output is confirmed
on.
The green led will light up
continuously.
Steady green light.
4
Spare output is confirmed
on.
The green led will flash
slowly.
Slow green flash.
5
Main output reports a
malfunction.
Unacknowledged alarm.
The buzzer will sound and
both the green and red
LEDs on the button will
flash.
Alternating red and green
flash.
6
Spare output reports a
malfunction.
Unacknowledged alarm.
The buzzer will sound and
the red led on the button
will flash.
Rapid red flash.
7
Spare output is defect and
has been confirmed by the
user.
The buzzer will stop and
the red led will turn on
continuously.
Steady red light. Turn off
panel to reset.
Rapid flash: 2 flashes per second.
Slow flash: 1 sec on, 1 sec off.
Button state diagram
With reference to the table above, the button states operate in a fixed state process.
State 0 is the default state where both the green and red led on a button is turned off
and associated outputs are in an off position.
The left branch on the diagram below shows the st ates when the user wants to turn on
a main output, e.g. the main lantern. By pressing the button for less than 5 seconds, the
button changes to state 1. In this state a message is sent to the corresponding output,
and the led flashes rapidly awaiting a con firmation from the output module. Another
press on the key at this state will return to state 0 and a message to turn the output off.