11 |
P a g e
C. Operating Instructions
Your physical installation should be complete. Power the dispenser on, which in turn
will power the FluidSecure LINK. You will notice a faint blue light in the top half of the
FluidSecure LINK when power is applied. If there is no light, reconfirm that power is
present. If no light is observed, recheck your electrical connections and try again. If no
light is still not observed, refer to the troubleshooting section using the manual.
Calibration of the Pulser vs the Meter:
The FluidSecure pulser must be calibrated unless you know 100% the ratio (example
10:1). The FluidSecure LINK along with the optional purchased pulser or if you are using
an already installed pulser, you must read how many pulses are produced per unit of
measure (gallons, liters, quarts, etc.). We will use the word gallon in this explanation, but
it can be any unit of measure. To calibrate the pulser you must have an authorized cell
phone. In the FluidSecure Information page, in the FluidSecure CLOUD, you will need to
enter in the number of gallons pumped during calibration. The pulses field can be any
initial number. You must contact your FluidSecure administrator to obtain authorization
to run a calibration. Once authorized, you will have to either pump fuel into a calibrated
container or use the existing meter on your dispenser to calibrate. If you have just
installed the pulser (and you probably have at this point) you must pump at least 20 to
30 gallons back into the tank to purge the air out of the pulser and hose. For calibration,
It is best to pump at least 5 gallons for high accuracy but a smaller amount can be utilized.
To begin the calibration, refer to your cell phone user guide for the FluidSecure APP.
Start a transaction and begin pumping into your calibrated container. If you are using
your existing meter, then simply pump the fuel back into the tank or into a vehicle. Stop
at a full gallon mark as close as you can. It doesn’t matter how many gallons you pump
but the more the better. (Please note that we refer to gallons, but the label is unimportant.
You can use quarts, liters or anything else.) When you are finished, the cell phone will
display a count. Call the administrator and report to them total gallons you pumped and
the counts. That is all there is to it.
D. Quick CLOUD Startup Guide
Once installation is complete you will need to enter some data into the FluidSecure
CLOUD webpage. Once the system is shipped, a Company page will be setup
automatically allowing you to start using the software.
The CLOUD-based software must be filled out in proper sequence before any testing
can be performed and transactions at the fuel locations can be started. Any users must