5353-M1-001-EN-02
Output leads are connected using the polarised
connectors on the unit and lead set.
Ensure units is disconnected from AC power
before connecting to vehicle. Only when the
central “polarity” led lights green should AC
power be connected.
5.3.
Powering the unit
The primary method for powering the support
unit is via the AC power cord. The switch on the
unit is primarily designed to cut off the output
to DC leads.
CSU2 ONLY
Battery Support Mode:
Ensure output leads are not connected to CSU2
and unit is disconnected from mains power.
Connect output leads to vehicle battery
terminals.
Power up CSU2.
Wait for 2 beeps and connect output leads to
CSU2 via yellow connector.
Showroom Support Mode:
Ensure output leads are not connected to CSU2
and unit is disconnected from mains power.
Connect output leads to vehicle battery
terminals.
Connect output leads to CSU2 via yellow
connector.
Power up CSU2.
5.4.
Disconnecting from vehicle
Ensure unit is switched off AND AC power is
disconnected before disconnecting leads from
vehicle