TRACTION BSU2-50 Instruction Manual Download Page 3

5353-M1-001-EN-02 

 

Recommended minimum AWG size for extension cords for battery support units 

AC input rating Amperes 

AWG size of cord 

Length of cord, M 

 

7.5 

15 

30 

45 

8-10 

18 

14 

12 

10-12 

16 

14 

10 

12-14 

16 

12 

10 

14-16 

16 

12 

10 

16-18 

14 

12 

10 

 

4.

 

Overview 

 

4.1.

 

The Traction range of Battery Support Units 
convert nominally 110-120V ac 60Hz 8A to 
13.8V dc 50A. This enables you to operate a 12V 
nominal DC load up to the units rated output 
current as demanded by the attached load. 

 

4.2.

 

Each Battery Support Unit has been designed 
with high quality components to help ensure 
years of continuous use. The Support Units are 
protected by multiple protection features in 
order to ease of use: 

 

Reverse polarity protection 

 the centre LED 

should show green for good or red for incorrect 
connection. 
 

 

Over-current protection 
 
Over temperature protection 
 
Short circuit protection 
 
Backward voltage protection 

 if the voltage at 

the terminals is higher than the Support Unit 
supply a relay will be heard cutting in and then 
cutting out to check voltage level. 
 

5.

 

Installation 

 
There are no components within the Battery 
Support Units that, in their normal operation, 
produce arcs or sparks. All electronic devices 
have some potential for generating sparks in the 
event of failure. 

Therefore, never install this 

device in the same compartment with 
flammable items such as gasoline or batteries. 
 

5.1.

 

Installation Location 
 
BSU2-50 and BSU2-125 have been designed to 
be trolley mounted (Part number JLR-Trolley-
US). The trolley comes complete with mounting     

 
 
 
bracket. Battery support units should not be 
rested in engine bay due to risk of damage 
either to vehicle or equipment. Showroom 
support unit SSU2-50 has been designed to sit 
under the supported vehicle. Ensure that unit is 
placed on fitted rubber runners and that there 
is at least 5cm of clear space on all sides 
excluding base. Ensure the mains socket is near 
the equipment and easily accessible at all times.  
 

 

 
The unit can be wall mounted in a vertical 
orientation only with the connections at the 
bottom. 
 
Neither BSU2 or SSU2 should not be positioned 
so that the label is either upside down or 
invisible. 
 
 

5.2.

 

Connecting to a vehicle 
 
Please follow dealer standards guidelines for 
connection methods. Traction units are supplied 
with vehicle specific adapters that should be 
used at all times. Failure to use the adapters in 
the positions prescribed could result in 
excessive heat being generated in the lead set 
leading to premature failure of leads and low 
voltage output. 

Summary of Contents for BSU2-50

Page 1: ...5353 M1 001 EN 02 BATTERY SUPPORT PRODUCTS BSU2 50 CSU2 50 SSU2 50 BSU2 90 BSU2 125 ALL VARIANTS INSTRUCTION MANUAL ...

Page 2: ... 1 9 An extension cord should not be used unless absolutely necessary 1 10 Have a damaged cord or plug replaced immediately 1 11 Do not expose the battery support unit to rain or snow 2 Personal Precautions 2 1 The battery support unit is not intended to supply power to a low voltage electrical system other than applications using rechargeable flooded gel or AGM type batteries Do not use the batte...

Page 3: ...produce arcs or sparks All electronic devices have some potential for generating sparks in the event of failure Therefore never install this device in the same compartment with flammable items such as gasoline or batteries 5 1 Installation Location BSU2 50 and BSU2 125 have been designed to be trolley mounted Part number JLR Trolley US The trolley comes complete with mounting bracket Battery suppo...

Page 4: ...o DC leads CSU2 ONLY Battery Support Mode Ensure output leads are not connected to CSU2 and unit is disconnected from mains power Connect output leads to vehicle battery terminals Power up CSU2 Wait for 2 beeps and connect output leads to CSU2 via yellow connector Showroom Support Mode Ensure output leads are not connected to CSU2 and unit is disconnected from mains power Connect output leads to v...

Page 5: ...ps Check connections 7 Symbols The following symbols appear on the battery support units O I AC Power Illuminated when supply is reaching unit Polarity Green when good Red when reversed Output Illuminated when output is active 8 Warranty and Service For technical support call 866 628 5508 or email oetech service solutions com For repair service go to repairtrack bosch automotive com or call 800 34...

Page 6: ...ction facilities will be set up to divert WEEE away from landfill funded by producers and retailers of EEE 11 Technical Specification Environmental Information Parameter BSU2 50 B SSU2 50 B Working Temp C 0 to 40 Working Humidity 20 90 non condensing Storage Temp C 40 85 Storage Humidity 10 95 RH Input Voltage Range 110 120VAC Inrush Current max 8A 110VAC O P Rated Current 50A O P Rated Power 600W...

Reviews: