of supporting the worker. For rescue purposes, 

the anchorage point must support a minimum 

of 3,100  lbs. (13.8  kN) per attached worker. 

Consult local, state, federal and provincial 

regulations as revisions occur.

3.2.1  Every anchorage point must be selected with 

care. Make sure that there are no obstacles in 

the evacuation path and on the landing zone. 

Maintain a safe distance from any obstruction 

to ensure a safe descent (e.g. electric wires, 

glass, concrete reinforcing bars) (

Figure 7

).

3.2.2  Never use an anchorage point which will not 

allow the connector keeper to close. Anchor 

must be compatible with connector and 

must not be capable of causing a load to be 

applied to connector keeper. Before each use, 

ensure that all connectors are in good working 

condition and safely closed, especially the 

gates on the snap hook and/or carabiner.

4. INSTALLATION

 

WARNING

The derope

®

 descent device must only be installed 

and used by a trained person.

4.1 

derope

®

 T and derope

®

 Up A emergency 

escape/controlled descent devices

An inspection as per section  9 must be 

performed before use.

4.1.1 

Identify or prepare the anchorage point for the 

derope

®

 descent device.

4.1.2  Make sure that the anchorage point can 

withstand a minimum of 3,100 lbs. (13.8 kN) 

and is located above the evacuation point.

4.1.3  Attach the derope

®

 descent device to the 

anchorage point with the help of the supplied 

carabiner.

4.1.4  Throw the rope down, making sure that there 

are no entanglements or knots, that the rope 

does not come in contact with sharp edges and 

that it reaches the ground.

4.2 

derope

®

 Up E emergency escape/ 

controlled descent device

Inspect the ladder uprights and rungs for signs 

of deformation.

4.2.1  Set up the upper clamp jaw onto the ladder 

rung at the desired position to perform the 

rescue (

Figure 8a

).

Fig. 8

derope

®

 Up E mounted on ladder

Fig. 10

derope

®

 Up R mounted on tripod

Fig. 9

a.

c.

Index 

pin

b.

d.

Summary of Contents for derope Up A

Page 1: ...derope emergency escape controlled descent devices use and maintenance instructions Meets or exceeds standards requirements established by ANSI Z359 4 07 CSA Z259 2 3 type 1E...

Page 2: ...d efficiency of operations that this manual be read and fully understood by the worker before using any fall arrest system ALL instructions contained herein must be carefully read and strictly followe...

Page 3: ...he use of the derope emergency escape controlled descent device must comply with applicable safety regulations either local state federal and regional and be compatible with one another and with the d...

Page 4: ...onsequences of dismantling or altering the derope emergency escape controlled descent device beyond description in this manual by anyone who is not authorised by Tractel Tractel declines any responsib...

Page 5: ...ope emergency escape controlled descent device beyond the information and description given in this manual IN CASE OF FALL ARREST xxix The rescue operation should not take more than 15 minutes Longer...

Page 6: ...n for a single user through the operation of the centrifugal brake 1 4 Features 1 4 1 Hoisting or lowering function This feature allows a victim to be lifted by the rescue worker with the help of the...

Page 7: ...k Carabiner Pig tail Pig tail Casing Fig 6 derope Up R Fastening pin Locking screw Rope blocking device Rope guide Safety pin Fig 4 derope Up A Hand wheel Folding handle Fig 5 derope Up E Adjustable l...

Page 8: ...scent height and number of repeated descents in accordance with the limits indicated in Table 2 below DANGER Following each use whether for a single descent or repeated descents the derope descent dev...

Page 9: ...netrate into the weave and dry causing the rope to become hard brittle and eventually break the fibers Solvents and drying agents within paint cause damage similar to chemical exposure 2 7 3 Exposure...

Page 10: ...STALLATION WARNING The derope descent device must only be installed and used by a trained person 4 1 derope T and derope Up A emergency escape controlled descent devices An inspection as per section 9...

Page 11: ...e tracpode tripod the latter must be equipped with a diverter pulley or two 2 pulleys if another piece of equipment is used on the same tracpode tripod e g blocfor self retracting lanyard or work winc...

Page 12: ...sistance during movement increases with the speed of movement WARNING Always use a self locking snap hook for an attachment in any personal rescue system 5 2 Evacuation function During a intentional v...

Page 13: ...the derope decent device has been properly secured above the victim as described in section 4 the self locking snap hook at the extremity of the rope must be hooked into the frontal or back D ring on...

Page 14: ...nsure the victim is properly connected to the extremity of the evacuation rope 5 5 5 Both persons can now evacuate by releasing the rope being held The descending speed will be controlled automaticall...

Page 15: ...15 Fig 15...

Page 16: ...s are apparent and are not described below remove the item from service replace it and contact Tractel for advice 9 2 1 If corrosive environments are unavoidable or the units are to be used for traini...

Page 17: ...quipment was sold to the original purchaser Return shipment must be prepaid 10 3 Any parts proved to be defective upon inspection by Tractel will be repaired or replaced at no cost 10 4 The obligation...

Page 18: ...t device model Lot number of the manufacturer Serial number of the manufacturer Owner User Date of purchase First use Date of inspection Inspection results details of identified defects Signature of c...

Page 19: ...Trainer User Evacuation height and weight of trainee Hoisting height and weight of trainee Trainer s signature Maximum number of repeated descents Descent height 165 ft 50 m 410 ft 125 m 650 ft 200 m...

Page 20: ...Drive Norwood MA 02062 Tel 781 401 3288 Fax 781 828 3642 LOS ANGELES 1 800 675 6727 tractel usa west tractel com 168 Mason way Unit B2 City of Industry CA 91746 Tel 626 937 6727 Fax 626 937 6730 UNITE...

Reviews: