TRACKMASTER
Ch. 12
Removal and Replacement of Components
317-160-406 Rev 4
TMX428 TMX428CP & TMX58 Service Manual
127
May 2021
Firmware Download FGLF0698-00 (4
th
Edition LCD Control)
1.
Copy the Console.ROM to a Mini Micro SD card (consult factory for the
correct firmware version).
2.
Locate the main power switch and set the switch in the off position.
3.
Remove the upper plastic console screws (10X) to gain access to
the LCD Screen circuit board.
4.
Insert the SD card in to the SD card reader slot as shown at right.
5.
Switch the main power switch to the ON position. Be sure to keep hands away from electrical
components which may cause a shock hazard.
6.
There is a LED at LED1 that will flash at a slow rate of 0.5 seconds per flash while the system is
searching for the SD card and reprogramming the processor. During the download process the LCD
screen will remain black until the new firmware has been fully loaded.
7.
Once the program is loaded, the LED should rapidly flash. The blue screen will display the Welcome
Screen.
Dip Switch Configuration
Position Dip Switch 1: In
the “OFF” position, units are set to English “MPH”
.
In
the “ON” position, units are set to Metric “KPH”.
Position Dip Switch 2: In
the “OFF”
position, a communication disconnect
stop timeout is 2.5 seconds. In
the “ON” position, the communication disconnect
stop timeout is extended to 4 seconds.
Position Dip Switch 3 (FirmwareVersion 1.43 & later FGLF0495-1 Smart Power Supply): When in the
“OFF” position for Trackmaster Interface Protocol, in the “ON” position New Customer Interface Protocol.
Position Dip Switch 4: In
the “OFF”
, for factory use only.
Additional dip switch (Firmware Version 1.1812 and later FGLF-4953-03 Smart
Power Supply). This configuration has 1-6 number switches, position 1 thru 4
are same as (FGLF0495-1 Smart Power Supply).
Position dip switch 5 (Firmware Version 1.1812 and later FGLF-4953-03 Smart
Power Supply) stores the ability to retrieve trouble shooting log file. When retrieving
system flash log file switch configuration 1,2,3,4, and 6 are in the “OFF position and switch 5 is in the
“ON” position.
Position dip switch 6 unassigned (Firmware Version 1.1812 and later FGLF-4953-03 Smart Power
Supply).