PM DR 175/250 Single Inverter Diagram
4-5
PM DR 175/250 S Assembly Sequence
1.
Feet (Page 6-17)
2.
Edge guards
3.
C40 if equipped (Page 5-7)
4.
Neutral and ground bonding block (left panel for SW, right panel for DR, Page 5-21)
5.
DC bonding block (left for DR, right for SW, Page 5-15)
6.
DC shunt
7.
DC bus bars
8.
DC175/250 (Page 13)
9.
DC20/60/110 (Page 12)
10. IOX60 (Page 19)
11. any additional AC or DC breakers
12. Slider (Page 23)
13. Cover (Page 13)
14. connect ground conductors
15. AC output cables
16. AC neutral cables
17. DC cables
18. Decals
19. Lid (Page 19)
20. Door (Page 15)
Assembly Instructions: Invert PM and install feet; turn PM upright to continue. Remove appropriate
component instruction sheets and arrange in order of installation. Gather all tools and components
listed in the instructions and place them nearby. Prepare components as instructed on the
component assembly pages and set aside. When all cables, components, fasteners, etc. are
prepared and handy, assemble each component in the sequence as shown, referring to the
component assembly instructions as required.
When ordering parts, always use the PMO- prefix.