3.6.2.8 Revolutions denominator
This parameter (together with the parameter "Revolutions numerator") defines the
total number of revolutions displayed by the encoder before it starts again from zero.
Inputs
(Box+rotary encoder TR Gear)
Lower limit
1
Upper limit
99
Default
1
3.6.2.9 Code SSI-Interfacebox
Defines the output code for the SSI interface. The transfer to the PROFIBUS takes
place in binary form according to the PNO profile.
Selection
(Box+rotary encoder TR Gear)
Default
Gray
(SSI-BOX supplies 24-bit Gray code)
X
Binary
(SSI-BOX supplies 24-bit binary code)
Shifted Gray
(SSI-BOX supplies 24-bit shifted Gray code)
3.6.2.10 Code PROFIBUS interface:
Defines the output code for the PROFIBUS interface.
Selection
(Box+rotary encoder TR Gear)
Default
Gray
(SSI-BOX supplies 24-bit Gray code)
Binary
(SSI-BOX supplies 24-bit binary code)
X
Shifted Gray
(SSI-BOX supplies 24-bit shifted Gray code)
3.6.2.11 Preset 1 value [units] hi and preset 1 value [units] lo
(Box+rotary encoder TR Gear)
Together, these parameters define the position value to which the SSI-BOX is
adjusted with the leading edge of the 1st preset input.
The inputs depend on the total measuring length in increments (see also chapter 3.6.2.6)
Lower limit
0
Upper limit
programmed total measuring length in increments - 1
Warning
To execute a preset the preset-inputs of the SSI-BOX have to be used.
Possible available preset-inputs of the encoder may not be used to set the position.