Linear encoder, TR configuration
"Box+rotary encoder TR Gear" (only up to software versions 010)
SSI without checksum (CRC)
Specified SSI-BOX configuration
Code sequence
arbitrary
Encoder CRC
checksum monitoring switched off
Total measuring range (units) hi
256
Total measuring range (units) lo
0
Revolutions numerator hi
0
Revolutions numerator lo
4096
Revolutions denominator
1
Code SSI-Interface
arbitrary
Code PROFIBUS-Interface
arbitrary
Preset 1 value (units) hi
arbitrary, within the limits
Preset 1 value (units) lo
arbitrary, within the limits
Preset 2 value (units) hi
arbitrary, within the limits
Preset 2 value (units) lo
arbitrary, within the limits
Specified linear encoder type or programming (without CRC, or switched off)
Full resolution
0.1 mm or. 0.01 mm
Output code
binary
Number of data bits
24
Measuring length in increments
within 24 bit
SSI with checksum (CRC)
Not possible !