![TR-Electronic SSI-BOX Operating Manual Download Page 41](http://html1.mh-extra.com/html/tr-electronic/ssi-box/ssi-box_operating-manual_1146730041.webp)
Operating Manual SSI-BOX PROFIBUS-DP (PNO)
ELECTRONIC GmbH
TR - ELECTRONIC GmbH,
Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. ++49 (0)7425-228-0, Fax ++49 (0)7425-228-33
Date: 25.04.2012
TR - E - BA - GB - 0013 - 03
Page 41 of 45
4.5 Preset adjustment
The PROFIBUS can be used to adjust the SSI-BOX to any position value within a
range of 24 bit respectively 15 bit.
This is done by setting the most significant bits of the output data (2
31
for configuration
Class 2 - 32 bits or 2
15
for configuration Class 2 - 16 bits).
Outputs
Inputs
The preset adjustment value transferred in data bytes 0 - 3 is accepted as the position
value with the leading edge of bit 32 (=bit 7 of data byte 3). The SSI-BOX then
continues counting from this position. A readjustment is not possible until the control
bit has been reset again.
This process is not acknowledged via the inputs.