Technical data
TR-Electronic GmbH 2011, All Rights Reserved
Printed in the Federal Republic of Germany
Page 90 of 139
TR - ELE - BA - DGB - 0022 - 04
02/08/2016
4.2 Specifications
Typical measuring accuracy for:
LLB65-00100
1)
LLB65-00101
1)
LLB500-00100
1)
LLB500-00101
1)
1.5 mm at 2
3.0 mm at 2
1.0 mm at 2
3.0 mm at 2
Accuracy of the analog output
LLB-65:
LLB-500:
0.2 % full scale
0.1 % full scale
Smallest unit displayed
0.1 mm
Measuring range on natural surfaces
0.05 to approx. 65 m
Measuring range on orange (reflective) target plate,
LLB-500:
See chapter 10 Accessories
0.5 to approx.500 m
Measuring reference
from front edge, see chapter 4.3, page 91
Diameter of laser spot at target with a distance of
4 mm at 5 m
8 mm at 10 m
approx. 28mm*14mm at 50m
approx. 40mm*25mm at 100m
Time for a measurement
Single measurement:
Tracking at
LLB-65:
LLB-500:
0.3 to approx. 4 sec
0.15 to approx. 4 sec
0.04 to approx. 4 sec
Light source
Laser diode 620-690 nm (red)
IEC 60825-1:2007; Class 2
FDA 21CFR 1040.10 and 1040.11
Beam divergence: 0.16 x 0.6 mrad
Pulse duration: 0.45x10
-9
s
Maximum radiant power: 0.95 mW
ESD
IEC 61000-4-2: 1995 +A1 +A2
EMC
EN 61000-6-4
EN 61000-6-2
Power supply
13 ... 30V DC, 0.6A
Dimensions
150 x 80 x 72 mm
Operation temperature
2)
-10 °C to +50 °C
Storage temperature
-40 °C to +70 °C
Degree of Protection
IP65; IEC60529
(protected against ingress of dust and water)
Weight
950 g
Interfaces
1 PROFIBUS-DP-interface, EN50170/EN50254
1 programmable analog output 0/4 ... 20mA
2 programmable digital outputs
1 programmable digital input
1 digital output for error status
1)
See 4.1 Measuring accuracy on page 89.
2)
In case of permanent continuous measurement the max. temperature is reduced to 45°C