Parameterization and configuration
TR-Electronic GmbH 2011, All Rights Reserved
Printed in the Federal Republic of Germany
Page 112 of 139
TR - ELE - BA - DGB - 0022 - 04
02/08/2016
Operating parameter Offset value
Description see page 117
DDLM_Set_Prm
Signed32
Byte
x+1
x+2
x+3
x+4
Bit
31
– 24
23
– 16
15
– 8
7
– 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
0 (
–19685040 - +19685040)
Offset value
Operating parameter Measuring cycle
Description see page 118
DDLM_Set_Prm
Unsigned8
Byte
x+5
Bit
7
– 0
Data
2
7
– 2
0
Default (dec.)
0 (0
– 255)
Measuring cycle
Bit coded operating parameter
DDLM_Set_Prm
Byte
x+6
Bit
7
– 0
Data
2
7
– 2
0
x = default setting
Bit Definition
= 0
= 1
Page
0
Count direction
with increasing distance to
the laser, values increasing
X
with increasing distance to
the laser, values decreasing
1
Offset
Offset active
X
Preset adjustment active
2
Error output
Error output =
last valid value
X
Error output =
entered Error value
3
Min current
0 mA
X
4 mA