TRWinProg Parameterization
TR-Electronic GmbH 2019, All Rights Reserved
Printed in the Federal Republic of Germany
Page 44 of 47
TR - ECE - BA - DGB - 0146 - 00
01/17/2019
5.2 ASI parameters
5.2.1 Baud rate
Via the parameter baud rate, the
transmission rate
can be set.
lower limit
1 000
upper limit
1 000 000 000
default
9600
5.2.2 Number of data bits
Sets the number of data bits for the user Data of one sign.
Default:
8 (cannot be changed)
5.2.3 Number of stop bits
Selection
Description
Default
1
The measuring system transmits one stop bit
x
2
The measuring system transmits two stop bits
5.2.4 Parity
Selection
Description
Default
off
no parity
x
even
even parity
odd
odd parity
Parity even
The parity bit serves as control bit for error detection during data transmission.
The parity represents the checksum of the bits in the data word. If the data word
contains an odd number of ones, the parity is even = "1" and adds the checksum to
even parity. The parity bit always follows the last data bit of the position output. It is
calculated from all previous bits. Therefore, only a single parity bit is possible.
Parity odd
The parity bit serves as control bit for error detection during data transmission.
The parity represents the checksum of the bits in the data word. If the data word
contains an even number of ones, the parity is odd = "1" and adds the checksum to
odd parity. The parity special bit always follows the last data bit of the position output.
It is calculated from all previous bits. Therefore, only a single parity bit is possible.