background image

 

Section 5 – Warranty

 

 

15

Section 5. –  Warranty 

TPS  Pty.  Ltd.  guarantees  all  instruments  and  sensors  to  be  free  from  defects  in  material  and 
workmanship when subjected to normal use and service. This guarantee is expressly limited to the 
servicing  and/or  adjustment  of  an  instrument  returned  to  the  Factory,  or  Authorised  Service 
Station, freight prepaid, within twelve (12) months from the date of delivery, and to the repairing, 
replacing, or adjusting of parts which upon inspection are found to be defective. Warranty period 
on sensors is three (3) months. 

There  are  no  express  or  implied  warranties  which  extend  beyond  the  face  hereof,  and  TPS  Pty. 
Ltd. is not liable for any incidental or consequential damages arising from the use or misuse of this 
equipment, or from interpretation of information derived from the equipment. 

Shipping damage is not covered by this warranty. 

PLEASE NOTE 

A guarantee card is packed with the instrument or sensor. This card must be completed at the time 
of purchase and the registration section returned to TPS Pty. Ltd. within 7 days. No claims will be 
recognised without the original guarantee card or other proof of purchase. This warranty becomes 
invalid  if modifications  or  repairs  are  attempted by  unauthorised  persons, or the  serial number  is 
missing. 

PROCEDURE FOR SERVICE 

If  you  feel  that  this  equipment  is  in  need  of  repair,  please  re-read  the  manual.  Sometimes, 
instruments are received for "repair" in perfect working order. This can occur where the sensor(s) 
simply requires cleaning or replacement or some other field serviceable event. 

TPS Pty. Ltd. has a fine reputation for prompt and efficient service. In just a few days, our factory 
service engineers and technicians will examine and repair your equipment to your full satisfaction. 

To obtain this service, please follow this procedure… 

Return  the  instrument  AND  ALL  SENSORS  to  TPS  freight  pre-paid  and  insured  in  its  original 
packing  or  suitable  equivalent.  INSIST  on  a  proof  of  delivery  receipt  from  the  carrier  for  your 
protection in the case of shipping claims for transit loss or damage. It is your responsibility as the 
sender to ensure that TPS receives the unit. 

Please check that the following is enclosed with your equipment: 

 

Your Name and daytime phone number. 

 

Your return street address. 

 

A description of the fault. (Please be SPECIFIC.) 
(Note: "Please Repair"  does NOT describe a fault.) 

Your equipment will be repaired and returned to you by air express where possible. 

For out-of-warranty units, a repair cost will be calculated from parts and labour costs. If payment is 
not  received  for  the  additional  charges  within  30  days,  or  if  you  decline  to  have  the  equipment 
repaired,  the  complete  unit  will  be  returned  to  you  freight  paid,  not  repaired.  For  full-account 
customers, the repair charges will be debited to your account. 

Summary of Contents for easyFLOW-VS

Page 1: ...td ABN 30 009 773 371 Unit 6 253 Leitchs Road Brendale QLD Australia 4500 Phone 07 3205 8027 International 61 7 3205 8027 Fax 07 3808 4871 International 61 7 3808 4871 Email tps tps com au Web www tps...

Page 2: ...ions 9 2 6 External Control Settings 10 2 7 Setting the Pump Speed to 50 11 Section 3 Operating Instructions 12 3 1 Manual Operation 12 3 2 External On Off Control Operation 12 3 3 External 4 20 mA or...

Page 3: ...mation section to ensure that you have received all accessories and any optional items you may have ordered Section 2 Installation This section provides details on installing the easyFLOW VS including...

Page 4: ...control mode using a 4 20mA or 0 1V input 3 External Control Indicator The External Control indicator LED lights when the easyFLOW VS is set for either external on off control or external speed contro...

Page 5: ...al drum Part No 116354 easyFLOW VS Handbook Part No 130050 24V 500mA 1A AC DC Adaptor Part No 130106 Australia 240V 2 Flat Pins 130108 Euro Asia 220V 2 Round Pins 130110 USA 110 120V 2 Flat Pins 13011...

Page 6: ...C 500mA 1 Amp AC DC Adaptor to suit country of destination is supplied The easyFLOW VS unit draws approximately 200 mA of current Standard Control Dose Rate control allows selection of OFF Dosing Rate...

Page 7: ...bottom of the chemical drums to the dosing pumps is 2 metres 3 The power lead from the AC DC Adaptor reaches from a mains power point to the easyFLOW VS without straining The external control cable be...

Page 8: ...provided is not compatible with the container drill a 1 2 or 13mm hole into the lid of the container and fit the compression fitting Drill a second 2mm diameter vent hole to avoid suction build up 2 4...

Page 9: ...lation 9 2 5 Mount the easyFLOW VS and Make Electrical Connections For wall mounting use minimum 3mm or 1 8 stainless steel bolts screws or masonary anchors A drilling template is provided at the back...

Page 10: ...cess the circuit board s settings remove the four screws at the corners of the front panel and remove the lid Please use caution to avoid damaging any connecting cables In the table below Switch under...

Page 11: ...fitting is provided for these users To select 50 speed operation 1 Remove the front panel and locate the jumper settings as per the instructions in section 2 6 2 Set jumper J3 to On to select 50 speed...

Page 12: ...W VS is under external control 3 It is not necessary to set the Dose Rate control as the pump speed is determined by the 4 20 mA or 0 1 V signal 3 4 External 4 20 mA or 0 1 V Control Operation with Ma...

Page 13: ...he Pump Tubing may be replaced every year as a precautionary measure To remove the old Pump Tube 1 IMPORTANT Place the pump suction tubing into a bucket of fresh water Prime the pump with water by swi...

Page 14: ...an be pushed in round facing in The new pump tube has now been fitted 2 3 4 Replace the see through protector plate on the front of the pump This is essential to protect the rollers and tube from dirt...

Page 15: ...ou feel that this equipment is in need of repair please re read the manual Sometimes instruments are received for repair in perfect working order This can occur where the sensor s simply requires clea...

Page 16: ...Section 5 Warranty 16 This page has been intentionally left blank to ensure that the drilling template is on its own removable page...

Page 17: ...Section 6 Drilling Template 17 Section 6 Drilling Template...

Reviews: