Section 4 – Peristaltic Dosing Pumps
14
To fit a new Pump Tube…
1
Turn the roller holder so
that the rollers are in a
horizontal line. Push the
left hand side
compression fitting into
its seat, round side
facing in. Begin turning
the roller holder
clockwise, so that the
roller holder acts as a
lever which pulls the
pump tube in as it turns.
After approximately 3/4
of a turn, the right hand
side compression fitting
can be pushed in, round
facing in.
The new pump tube has
now been fitted.
2
3
4
Replace the see-through
protector plate on the
front of the pump. This
is essential to protect
the rollers and tube from
dirt and moisture.
Re-fit the Input and
Output tubing to the
compression fittings.
See the procedure
detailed in section 2.4.
The power to the
easy
FLOW-VS
can
now be re-connected
and switched on.
Warning :
Use only a genuine replacement Tube supplied by TPS. Use of other tubing materials,
sizes or lengths may place undue stress on the rollers, causing them to wear
prematurely. This type of wear is not covered by warranty.