Combustion Test Procedure
Note: It is recommended you perform routine general maintenance on your
analyzer to ensure proper function. Please refer to Appendix A for general
maintenance schedule and function tests.
1. Turn the DC710 on and connect it to the TPI
View app as outlined on page 5. Make sure you
are in a “clean air” environment (no CO) and tap
“Start Pump”.
2. Connect the Mini Pump Protection
Filter assembly and Flue Probe Tubing
complete with In-Line Filter to the Gas
Sample Port and the 'K' Type
Thermocouple Plug from the Flue
Probe into Thermocouple (T1)
Socket.
The GK11M ambient air temperature
probe is connected to the (T2) socket.
If this probe is not used the analyzer
will use it’s internal temperature sen-
sor for ambient air (T2) reference.
WARNING
: - Ensure the 'K' type ther-
mocouple probes are inserted into the
sockets correctly. The plugs are
polarity marked and forcing the plug
into the socket the wrong way may
result in damage to the instrument.