On: 

Total power supply ≥ 243 W.

Flashing: 

Total power supply ≥ 243 W and lasts for more than 2 minutes.

Off: 

Total power supply ≤ 243 W.

Switches

Switch

Indication

Extend Mode

Extend Mode switch 

1–8

9–16

 and 

17–24

 can control the rate and power supply distance 

of corresponding ports.

Off

: The corresponding ports (1–8/9–16/17–24) run at 10/100 Mbps and support PoE 

power supply up to 100 m away.

On

: The corresponding ports (1–8/9–16/17–24) run at 10 Mbps and support PoE power 

supply up to 250 m away.

Priority Mode

(1–8)

Off: 

All the ports transmit data with the same priority.

On: 

Port 1–8 transmit data with a higher priority than Port 9–24. When congestion occurs, 

packets which are transmitted by the ports with a higher priority occupy the whole 

bandwidth.

Isolation 

(1–24)

Off

: Port 1–24 can transmit data with every port.

On

: Port 1–24 cannot transmit data with each other. They can transmit data only with port 

25–26.

10/100 Mbps RJ45 Port (Port 1–24)

The ports are designed to connect to devices with a bandwidth of 10 Mbps or 100 Mbps. The ports can 

provide power and transmit data for PDs. The maximum PoE power is 30 W for each PoE port and 250 W 

for all the PoE ports. The ports can also connect to non-PoE devices, but only transmit data.

10/100/1000 Mbps RJ45 Port (Port 25–26)

The ports are designed to connect to devices with a bandwidth of 10 Mbps, 100 Mbps or 1000 Mbps.

SFP Port (Port 25F–26F)

The ports are designed to install the SFP module. An SFP Port (Port 25F–26F) and the associated 

10/100/1000 Mbps RJ45 Port (Port 25–26) are called a “Combo” port, which means they cannot be used 

simultaneously; otherwise, only the SFP port works.

 

Rear Panel

The rear panel is shown as the following figure. Here we take TL-SL1218MP as an example.

Figure 1-4 

Rear Panel

Kensington Security Slot

Power Socket Grounding Terminal

Summary of Contents for TL-SL1218MP

Page 1: ...Business Networking Solution Installation Guide Unmanaged PoE Switch...

Page 2: ......

Page 3: ...rts in Extend Mode will downgrade to 10 Mbps The actual transmission distance may vary due to power consumption of PoE powered devices or the cable quality and type PoE budget calculations are based o...

Page 4: ...tion 6 2 1 Package Contents 6 2 2 Safety Precautions 6 2 3 Installation Tools 8 2 4 Product Installation 8 Chapter 3 Connection 10 3 1 Ethernet Port 10 3 2 SFP Port 10 3 3 Verify Installation 10 3 4 P...

Page 5: ...er along with data to remote devices over standard twisted pair cable in an Ethernet network PD is a device powered by a PSE and thus consumes energy Examples include powering IP telephones wireless L...

Page 6: ...s of the port PoE Max For TL SL1218P On Total power supply 143 W Flashing Total power supply 143 W and lasts for more than 2 minutes Off Total power supply 143 W For TL SL1218MP On Total power supply...

Page 7: ...nt panel of TL SL1226P is shown as the following figure Figure 1 3 Front Panel of TL SL1226P 10 100 Mbps RJ45 Port Port 1 24 LEDs Switches 10 100 1000 Mbps RJ45 Port Port 25 26 SFP Port Port 25F 26F L...

Page 8: ...24 can transmit data with every port On Port 1 24 cannot transmit data with each other They can transmit data only with port 25 26 10 100 Mbps RJ45 Port Port 1 24 The ports are designed to connect to...

Page 9: ...oltage 100 240 V 50 60 Hz Caution You should use the provided power cord Grounding Terminal The switch already comes with lightning protection mechanism You can also ground the switch through the PE P...

Page 10: ...utions Keep the power off during the installation Wear an ESD preventive wrist strap and make sure that the wrist strap has a good skin contact and is well grounded Use only the power cord provided wi...

Page 11: ...ectricity on the operation of the switch please attach much importance to the following items Dust the device regularly and keep the indoor air clean Keep the device well grounded and ensure static el...

Page 12: ...he rack or workbench is flat stable and sturdy enough to support the weight of 5 5 kg at least The rack or workbench has a good ventilation system The equipment room is well ventilated The rack is wel...

Page 13: ...e with supplied screws as illustrated in the following figure Figure 2 2 Bracket Installation Rack mounting Bracket Screw 3 After the brackets are attached to the device use suitable screws not provid...

Page 14: ...n of SFP port to an SFP module Figure 3 2 Inserting the SFP Module SFP Slot SFP Module 3 3 Verify Installation After completing the installation please verify the following items There should be 5 to...

Page 15: ...5 Initialization After the device is powered on it begins the Power On Self Test A series of tests run automatically to ensure the device functions properly During this time its LED indicators will r...

Page 16: ...le connectors are firmly plugged into the switch and the device A2 Make sure the connected device is turned on and working well A3 The cable length should be less than 100 meters 328 feet If Extend Mo...

Page 17: ...For TL SL1218MP 16 10 100 Mbps RJ45 Ports Auto Negotiation Auto MDI MDIX 2 10 100 1000 Mbps RJ45 Ports Auto Negotiation Auto MDI MDIX 2 1000 Mbps SFP Slots Combo PoE Port RJ45 For TL SL1218P PoE Port...

Page 18: ...1 65 EU and EU 2015 863 The original EU declaration of conformity may be found at https www tp link com en ce Safety Information Keep the device away from water fire humidity or hot environments Do no...

Page 19: ......

Page 20: ...ineers please visit https community tp link com to join TP Link Community For technical support the user guide and other information please visit https www tp link com support or simply scan the QR co...

Reviews: