ΚΛΙΜΑΤΙΣΤΙΚΟ TOIXOY DC INVERTER
WALL MOUNTED AIR CONDITIONER INVERTER TYPE
CONDIZIONATORE SPLIT

 

ΜΟΝΤΕΛΑ / MODELS / MODELLI 
UTN/UTG-09AP
UTN/UTG-12AP

Ευχαριστούμε για την επιλογή σας στα κλιματιστικά οικιακής χρήσης TOYOTOMI. 
Πριν χρησιμοποιήσετε αυτή τη συσκευή, παρακαλούμε διαβάστε προσεκτικά αυτό το 
εγχειρίδιο χρήσεως. Κρατήστε αυτό το εγχειρίδιο χρήσεως για μελλοντική αναφορά σε αυτό. 

Thank you for your choice in TOYOTOMI Wall Mounted Air Conditioners.
Before using this product, be sure to read this Instruction Manual carefully to ensure proper 
usage. Keep this manual in good shape for future reference.  

Grazie per aver scelto un prodotto TOYOTOMI.
Per un corretto funzionamento, leggere attentamente questo manuale prima di usare il 
condizionatore e conservarlo per una futura consultazione.

Summary of Contents for UTG-09AP

Page 1: ...your choice in TOYOTOMI Wall Mounted Air Conditioners Before using this product be sure to read this Instruction Manual carefully to ensure proper usage Keep this manual in good shape for future refe...

Page 2: ...2 4 5 6 10 11 12 13 14 18 19 19 20 20 22 23 27 28 31 31 32 32 33 39 39 43 44 44 46 46 48 48 48 49 50 51 54 54 57...

Page 3: ...3 GR 1 2 3 4 5 6 7 service...

Page 4: ...4 GR R32 service R32 GWP 675 R32 R32 R32...

Page 5: ...5 GR service 4m2 R32 1 band wifi 2400MHz 2483 5MHz 2 wifi 20dBm...

Page 6: ...6 GR q q q q q q q q q blue fins q...

Page 7: ...7 GR q q q service q q q q service q q...

Page 8: ...8 GR q q q q q q 3 q q q q...

Page 9: ...9 GR q q q q q q q NEC CEC q q q q q...

Page 10: ...10 GR q q q q q q q q q q m2 49 q...

Page 11: ...11 GR DB WB C DB WB C 32 23 43 26 27 24 18 15 C 43 C Temp indicator Power indicator aux...

Page 12: ...12 GR...

Page 13: ...13 GR On Off Mode Fan Swing Sleep Temp Timer WiFi Light 8 C WiFi I SENSE Light ON OFF Turbo Turbo...

Page 14: ...14 GR q q beep q q Light 1 On Off 2 Mode AUTO COOL DRY FAN HEAT 3 Fan AUTO AUTO AUTO COOLD RY FAN HEAT LD...

Page 15: ...15 GR X FAN FAN 2 AUTO FAN HEAT 2 FAN 4 c d c d AUTO TIMER c d 5 Swing 6 Sleep Sleep 7 Temp...

Page 16: ...16 GR 8 Turbo 9 10 TIMER TIMER OFF HOUR ON OFF c d c d 0 5 24 HOUR ON OFF TIMER no display...

Page 17: ...17 GR 11 WiFI WiFi WiFi MODE WiFi wifi module 12 LIGHT c d c d MODE d MODE d C F TEMP TIMER TEMP TIMER SE...

Page 18: ...18 GR TEMP TIMER 8 C TEMP TIMER 8 C 8 C AUTO CLEAN MODE FAN 5 AUTO CLEAN AUTO CLEAN CL AUTO CLEAN AUTO CLEAN...

Page 19: ...19 GR 1 2 7 1 5V 3 8 aux AUTO...

Page 20: ...20 GR 1 2 aux...

Page 21: ...21 GR 3 45 C 4 1 2 3 4...

Page 22: ...22 GR service 5 service 1 2 3 service 1 2...

Page 23: ...23 GR service 3 8...

Page 24: ...24 GR 3...

Page 25: ...25 GR AUTO AUTO 16 C 30 C...

Page 26: ...26 GR 5 8 U8 H6 H3 E1 service C5 F1 F2 F0 service service...

Page 27: ...27 GR service 210 5386490 service...

Page 28: ...28 GR 15cm 250 cm 15cm 300cm 15cm...

Page 29: ...29 GR 50cm 30cm 30cm 50cm 200cm...

Page 30: ...30 GR service 1 2 3 4 5 6 7 8 1 2 3 4 5 6 2 5 7 8...

Page 31: ...31 GR 1 2 3 4 5 1 2 3 4 5 6 7 8...

Page 32: ...32 GR 9 R32 1 2 3 4 5 9 12 10 17 21 16...

Page 33: ...33 GR 1 2 3 1 150mm 150mm 55mm 70mm 55mm 70mm...

Page 34: ...34 GR 2 3 55 70 5 10 1 2 55 70 5 10...

Page 35: ...35 GR 1 2 3 4 1 m 1 4 15 20 3 8 30 40 1 2 45 55 5 8 60 65 3 4 70 75...

Page 36: ...36 GR 2 1...

Page 37: ...37 GR 2 3 4 5 M M 9K 12K 17 21 3 N 1 2 N 1 3 2...

Page 38: ...38 GR 1 2 3 4 1 2 3...

Page 39: ...39 GR 4 5 1 2 3 3...

Page 40: ...40 GR 2300W 5000W 6000W 8000W 10000W 16000W 1 2 1 2 1...

Page 41: ...41 GR 2 3 4 1 m 1 4 15 20 3 8 30 40 1 2 45 55 5 8 60 65 3 4 70 75...

Page 42: ...42 GR L N N 1 2 N L 3 L M M M M 9K 12K 17 21 2 1 10 U...

Page 43: ...43 GR 2 U O O O H...

Page 44: ...44 GR 1 2 3 0 1 4 1 2 0 1MPA 5 6 2 7 Lo Hi...

Page 45: ...45 GR mm A mm A mm 6 6 35 1 4 1 3 0 7 9 52 3 8 1 6 1 0 12 12 7 1 2 1 8 1 0 15 8 16 5 8 2 4 2 2 90...

Page 46: ...46 GR 1 2 3 1 2 ON OFF MODE AUTO COOL DRY FAN HEAT 16oC 1 5 7 5 8 2 3 3...

Page 47: ...5000 BTU h 1465W 7000 BTU h 2051W 9000 BTU h 2637W 15 12000 BTU h 3516W 20 18000 BTU h 5274W 24000 BTU h 7032W 25 28000 BTU h 8204W 36000 BTU h 10548W 42000 BTU h 12306W 48000 BTU h 14064W 30 4 10 5m...

Page 48: ...48 GR g m g m g m 1 4 3 8 1 2 16 12 16 1 4 3 8 5 8 3 4 40 12 40 1 2 3 4 7 8 80 24 96 5 8 1 1 1 4 136 48 96 3 4 200 200 200 7 8 280 280 280...

Page 49: ...4 5 16 8 19 3 22 24 8 27 8 5 2 6 1 7 7 9 8 9 10 1 6 1 9 2 1 2 4 2 8 3 1 1 1 1 3 1 4 1 6 1 8 2 1 m2 kg 1 9 2 2 1 2 2 2 3 2 4 2 5 31 34 3 37 8 41 5 45 4 49 4 53 6 11 2 12 4 13 6 15 16 3 17 8 19 3 3 4 3...

Page 50: ...50 GR 2...

Page 51: ...51 GR R32...

Page 52: ...52 GR 1 2...

Page 53: ...53 GR 3 30 40 1 4 5 6...

Page 54: ...54 GR 7 8 Ampere...

Page 55: ...55 GR...

Page 56: ...56 GR 80...

Page 57: ...57 GR...

Page 58: ...TENANCE 73 74 TROUBLE CAUSE SOLUTION 75 77 INSTALLATION DIMENSION DIAGRAM 78 81 SAFETY PRECAUTION 81 GROUNDING REQUIREMENT 82 INSTALLATION OF INDOOR UNIT 82 88 INSTALLATION OF OUTDOOR UNIT 88 92 VACUU...

Page 59: ...ain or use the product with other equipment without abiding by the instruction manual of manufacturer After verification the defect of product is directly caused by corrosive gas Afterverification the...

Page 60: ...ns to accelerate the defrosting process or to clean other than those recommended by the manufacture Should repair be necessary contact your nearest authorized Service Center Any repairs carried out by...

Page 61: ...onditioner Otherwise it may cause electric shock q If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons to avoid a hazard q DO NOT was...

Page 62: ...operates under abnormal conditions it may cause malfunction electric shock or fire hazard q When turning on or turning off the unit by emergency operation switch please press this switch with an insu...

Page 63: ...d by the manufacturer its service agent or similarly qualified persons to avoid a hazard q The temperature of refrigerant circuit will be high please keep the interconnection cable away from the coppe...

Page 64: ...or children and far away from animals or plants If it is unavoidable please add the fence for safety purpose q The indoor unit should be installed close to the wall q Instructions for installation and...

Page 65: ...eating 27 24 18 NOTICE The operating temperature range outdoor temperature for heat pump unit is 15 C 43 C PARTS NAME DISPLAY Temp indicator Power indicator Notice Actual product may be different from...

Page 66: ...66 GB OUTDOOR UNIT Air inlet Air outlet...

Page 67: ...signal Health function Child lock Ventilation operation Not available 8 C heating function Set temperature Sleep mode WiFi function I SENSE function Not available Light function X fan mode timer ON t...

Page 68: ...ioner q Under off status set temperature and clock icon will be displayed on the display of remote controller If timer on timer off and light functions are set the corresponding icons will be displaye...

Page 69: ...LOCK press c or d button to adjust time Refer to CLOCK TIMER ON TIMER OFF buttons When setting TIMER ON or TIMER OFF press c or d button to adjust the time 5 SWING button Press this button to set up a...

Page 70: ...tton or d button to adjust timer setting time will change quickly if holding continually c or d button Time setting range is 0 5 24 hours Press this button again to confirm timer setting and the chara...

Page 71: ...is adopted Repeat the operation to quit the function AUTO CLEAN FUNCTION Under unit off status hold MODE and FAN buttons simultaneously for 5 seconds to turn on or off the AUTO CLEAN function When the...

Page 72: ...fluorescent lamp or wireless telephone remote controller should be close to indoor unit during operation Replace new batteries of the same model when replacement is required When you do not use remot...

Page 73: ...remove the panel when cleaning it Clean Filter 1 Open panel Pull out the panel to a certain angle as shown in the fig 2 Remove filter Remove filter as indicated in the fig 3 Clean filter Use dust cat...

Page 74: ...contact dealer 5 Check whether drainage pipe is damaged Note Basic points that needs to be checked before you stop using your air conditioner for a long time 1 Disconnect power supply 2 Clean filter...

Page 75: ...r unit Is sensitivity of remote controller low fuzzy dis play and no display Check the batteries If the power of batteries is too low please replace them No display when operating remote controller Ch...

Page 76: ...indoor air is cooled rapidly After a while indoor temperature and humidity will be de crease and mist will disap pear Set temperature cannot be adjusted Unit is operating under auto mode Temperature...

Page 77: ...he sound of friction caused by expansion and or contraction of panel or other parts due to the change of temperature Error Code When air conditioner status is abnormal temperature indicator on indoor...

Page 78: ...leakage from the indoor unit DO NOT repair or refit the air conditioner by yourself If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard IN...

Page 79: ...wrench Pipe cutter Leakage detector Vacuum pump Pressure meter Universal meter Inner hexagon spanner Measuring tape Space to the ceiling at least 50cm Drainage pipe Space to the wall at least 30cm Spa...

Page 80: ...appliance shall not be installed in the laundry 8 It is not allowed to be installed on the unstable or motive based structure such as a truck or in the corrosive environment such as chemical factory I...

Page 81: ...ulations use qualified power supply circuit and air switch 3 Make sure the power supply matches with the requirement of air conditioner Unstable power supply or incorrect wiring may result in electric...

Page 82: ...ositioned so that the plug is accessible 5 An all pole disconnection switch having a contact separation of at least 3 mm in all poles should be connected in fixed wiring Including an air switch with s...

Page 83: ...ase refer to the actual installation The wall panel is for illustrative purposes only please refer to the actual installation Please refer to the actual circumstances for the number of screws and the...

Page 84: ...case Step five Connect the pipe of indoor unit 1 Aim the pipe joint at the corresponding Bellmouth 2 Pretightening the union nut with hand 3 Adjust the torque force by referring to the following sheet...

Page 85: ...Note All wires of indoor unit and outdoor unit should be connected by a professional If the length of power connection wire is insufficient please contact the supplier for a new one DO NOT extend the...

Page 86: ...ut from the front side 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wire with wire clip pa...

Page 87: ...er and then separate the drain hose 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at the end Note The power cord and control wire cannot be crossed or winding The drain...

Page 88: ...ith expansion screws Note Take sufficient protective measures when installing the outdoor unit Make sure the support can withstand at least four times of the unit weight The outdoor unit should be ins...

Page 89: ...Place the outdoor unit on the support 2 Fix the foot holes of outdoor unit with bolts Step four Connect indoor and outdoor pipes 1 Remove the screw on the right handle of outdoor unit and then remove...

Page 90: ...ontrol wire only for cooling and heating unit to the wiring terminal according to the color fix them with screws pipe joint union nut Hex nut diameter Tightening torque m 1 4 15 20 3 8 30 40 1 2 45 55...

Page 91: ...bly and hidden possibly Min semidiameter of bending the pipe is 10 cm 2 If the outdoor unit is higher than the wall hole you must set a U shaped curve in the pipe before pipe goes into the room in ord...

Page 92: ...p and maintain this status for 1 2 minutes to check if the pressure of of piezometer remains in 0 1MPa If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liq...

Page 93: ...d prevent the burrs from getting into the pipe C Put on suitable insulating pipe D Put on the unit nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the...

Page 94: ...Test operation 1 Preparation of test operation Specify the important notes for air conditioner to the client 2 Method of test operation Put through the power press ON OFF button on the remote control...

Page 95: ...efrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe x additional refrigerant charging amount per meter Basing on the length of...

Page 96: ...r using the flammable refrigerant It can only be repaired by the method suggested by the equipment s manufacturer INSTALLATION NOTES The air conditioner is not allowed to use in a room that has runnin...

Page 97: ...eration process Checkwhetherthereisfiresourceorpotentialfiresourceinthemaintenance area The naked flame is prohibited in the maintenance area and the no smoking warning board should be hanged Check wh...

Page 98: ...ty instructions when installing or moving the unit To ensure the safety of you as well as the device please follow the safety instructions below CHECK AFTER INSTALLATION Check according to the followi...

Page 99: ...foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture resulting in injury 2 When installing or moving the unit do not charge the refrigerant which is not...

Page 100: ...or fire 8 Use the specified types of wires for electrical connections between the indoor and outdoor units Firmly clamp the wires so that their terminals receive not external stresses Electric wires w...

Page 101: ...mple shall be taken in case analysis is required prior to re use of reclaimed refrigerant It is essential that electrical power is available before the task is commenced a Become familiar with the equ...

Page 102: ...good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the...

Page 103: ...MA DI INSTALLAZIONE E SPAZI TECNICI MINIMI 124 127 PRECAUZIONI DI SICUREZZA 127 REQUISITI PER LA MESSA A TERRA 128 INSTALLAZIONE DELL UNIT INTERNA 129 134 INSTALLAZIONE DELL UNIT ESTERNA 135 139 POMPA...

Page 104: ...anutentareoutilizzareilprodottoconaltreapparecchiature senza attenersi al manuale di istruzioni del produttore Dopo la verifica il difetto del prodotto direttamente causato da gas o sostanze corrosivi...

Page 105: ...ta efficienza energetica I condizionatori hanno quindi bisogno di meno refrigerante all interno AVVERTENZA Non usare mezzi per accelerare il processo di sbrinamento o per pulire diversi da quelli racc...

Page 106: ...o da una persona responsabile per la loro sicurezza q I bambini devono essere sorvegliati affinch non giochino con l apparecchio q La pulizia e la manutenzione ordinaria non devono essere effettuate d...

Page 107: ...osse elettriche o danni Si prega di contattare il rivenditore quando necessario riparare il condizionatore q Non introdurre le dita o altri oggetti nella bocca di ingresso o di uscita dell aria Essa p...

Page 108: ...una separazione dei contatti di almeno 3mm su tutti i poli deve essere collegato a cablaggio fisso q Inserire un interruttore di dimensioni adeguate L interruttore deve avere le opportune protezioni m...

Page 109: ...egato a terra in modo efficace altrimenti potrebbe causare scosse elettriche q Il filo giallo verde nel condizionatore d aria il cavo di terra che non pu essere utilizzato per altri scopi q La resiste...

Page 110: ...fuochi caldaie a carbone riscaldamento elettrico q Non consentito praticare fori o bruciare il tubo di collegamento Queste attivit devono essere eseguite solo da un tecnico autorizzato per garantire l...

Page 111: ...eratura Indicatore di energia Avviso Il prodotto reale potrebbe essere diverso dalla grafica sopra Fare riferimento al prodotto reale UNIT ESTERNA Ingresso aria Pannello Filtro Pulsante ausiliario Def...

Page 112: ...icircolo Non disponibile Funzione 8 C riscaldamento Impostazione temperatura Modalit Sleep Funzione WiFi Funzione I SENSE Non disponibile Funzione Light Modalit X fan Timer ON Timer OFF Impostazione T...

Page 113: ...spegnere l apparecchio la temperatura impostata e l icona dell orologio vengono visualizzate sul display del telecomando se sono state impostate le funzioni timer ON timer OFF e light le icone corris...

Page 114: ...OFF o CLOCK Orologio premere il pulsante c o d per regolare l ora Fare riferimento ai pulsanti CLOCK Orologio TIMER ON TIMER OFF Quando si imposta TIMER ON o TIMER OFF premere il pulsante c o d per r...

Page 115: ...uesto pulsante per impostare il timer ON Premendo questo pulsante una volta le scritte HOUR ON OFF lampeggeranno per essere visualizzate Nel frattempo premendo il pulsante c o d per regolare l imposta...

Page 116: ...izza SE Ripetere l operazione per uscire dalla funzione Combinazione dei pulsanti TEMP e TIMER Impostazione della funzione 8 C di riscaldamento Premere contemporaneamente TEMP e TIMER in modalit HEAT...

Page 117: ...etta 3 Reinstallare il coperchio del vano batterie AVVISO Durante il funzionamento puntare l emettitore di segnale del telecomando verso il ricevitore dell unit interna La distanza tra l emettitore di...

Page 118: ...e il condizionatore e scollegare l alimentazione prima di iniziare le operazioni di pulizia e manutenzione per evitare scosse elettriche Non lavare il condizionatore con acqua per evitare scosse elett...

Page 119: ...icolo di incendio Non pulire i filtri sanificatori con acqua Questi filtri devono essere puliti solo con un aspirapolvere o semplicemente scuotendoli sul balcone Nota Punti fondamentali che devono ess...

Page 120: ...io sono materiali riciclabili Si prega di smaltirli in un appropriata isola ecologica 2 Se si desidera smaltire il condizionatore d aria rivolgersi al rivenditore o al centro di consulenza dell isola...

Page 121: ...i sfoca te o assenti Controllare le batterie Se la carica delle batterie troppo bassa sostituirle Non compaiono immagi ni quando si aziona il co mando infrarosso Controllare se il comando infrarosso d...

Page 122: ...sono alte L aria interna si raffredda rapidamente Attendere che la temperatura inter na e l umidit scendano provocando la scomparsa della nebbiolina Non possibile regolare la temperatura impostata L...

Page 123: ...zzatore stato appena acceso o spento il rumore dell attrito pro vocato dall espansione e o dalla contrazione del pannello o di altre parti a causa dei cambiamenti di temperatura Codice di errore Quand...

Page 124: ...ite dall unit interna Non cercare di riparare o reinstallare il climatizzatore da soli Se il climatizzatore funziona in condizioni anomale possono verificarsi malfunzionamenti scosse elettriche o peri...

Page 125: ...inamometrica Chiave Tagliatubi Cercafughe Pompa del vuoto Manometro Metro Universale Chiave esagoinale brugola Metro a nastro Distanza dalla parete almeno 50cm Tubo Scarico Condensa Spazio dalla paret...

Page 126: ...articolari circostanze 7 L apparecchio non deve essere installato nella lavanderia 8 Non consentito l installazione su una struttura instabile o basata su un motore come un camion o in un ambiente cor...

Page 127: ...t con le disposizioni di sicurezza locali utilizzare un circuito di alimentazione e un interruttore di corrente che siano a norma 3 Assicurarsi che l alimentazione corrisponda ai requisiti del climati...

Page 128: ...odo efficace altrimenti si possono verificare scosse elettriche 2 Il filo giallo verde del climatizzatore il filo di messa a terra che non pu essere utilizzato per altri scopi 3 La resistenza di terra...

Page 129: ...sulla parete con viti autofilettanti ST4 2X25TA poi verificare se stato installato saldamente tirando la staffa stessa Se il tassello a espansione in plastica allentato praticare con il trapano un alt...

Page 130: ...esterno con pendenza di 5 10 Nota Prestare attenzione alla formazione della polvere ed adottare misure di sicurezza rilevanti quando si esegue il foro Inserire il manicotto di plastica nel foro per e...

Page 131: ...dado con la chiave di coppia 4 Avvolgere la tubazione ed il giunto di collegamento con dell isolante quindi avvolgerlo con del nastro adesivo Fase sei Installazione tubo di scarico 1 Collegare il tubo...

Page 132: ...avo da soli Per il condizionatore d aria con presa assicurarsi che la presa sia raggiungibile dopo l installazione Per il condizionatore d aria senza spina necessario installare un interruttore dell a...

Page 133: ...posizionare il coperchio della morsettiera e serrare la vite 5 Chiudere il pannello Fase otto Fasciare il tubo 1 Fasciare il tubo di collegamento il cavo di alimentazione ed il tubo di scarico con la...

Page 134: ...non devono essere avvolti o arrotolati Il tubo di scarico va fasciato nella parte inferiore Fase nove Appendere l unit interna 1 Inserire i tubi una volta fasciati nel tubo a parete e farli passare at...

Page 135: ...l giunto di scarico condensa Per unit con capacit 2300 5000W sono necessari tasselli ad espansione da 6mm Per unit con capacit 6000 8000W sono necessari tasselli ad espansione da 8mm Per unit con capa...

Page 136: ...uovere la vite sulla maniglia sulla destra dell unit esterna e quindi rimuoverla Nota Quando ci sono pi cavi che lo attraversano il foro trasversale della maniglia deve essere rimosso ed eventualement...

Page 137: ...5 L N N 1 2 N L 3 L Blu Blu Blu Blu Marrone Nero Marrone Nero Nero Nero Marrone Marrone Giallo Verde ALIMENTAZIONE ALIMENTAZIONE Giallo Verde Giallo Verde Giallo Verde Collegamento unit interna Colleg...

Page 138: ...sti Il raggio di piegatura minimo di 10 cm 2 Se l unit esterna posizionata in alto rispetto al foro della parete necessario fare una curva ad U nel tubo come indicato in figura prima che la tubazione...

Page 139: ...o per verificare se la pressione del manometro rimane a 0 1MPa Se la pressione sale ci possono essere delle perdite 5 Rimuovere il manometro ed aprire le valvole del liquido e del gas completamente me...

Page 140: ...bavatura entri nella tubazione C Isolare adeguatamente la tubazione D Inserimento del dado Rimuovere i dadi dalle tubazioni dell unit interna e dai rubinetti dell unit esterna ed inserirli nella tubaz...

Page 141: ...1 Preparazione al test di prova Fornire al cliente le informazioni sul condizionatore 2 Metodo di esecuzione del test Collegare l unit all alimentazione premere il pulsante ON OFF del comando per mett...

Page 142: ...to viene aumentata di 10 m rispetto alla lunghezza standard aggiungere 5ml di olio refrigerante per ogni 5 m di tubo aggiunti Metodo per calcolare la quantit di carica refrigerante supplementare tubo...

Page 143: ...chiature di refrigerazione devono essere in possesso della certificazione e la qualifica per operare sui sistemi contenenti refrigeranti Se c bisogno di un altro tecnico per la manutenzione o la ripar...

Page 144: ...finestra 11 2 12 4 13 6 15 16 3 17 8 19 3 Installazione a parete 3 4 3 8 4 2 4 6 5 5 5 6 Installazione a soffitto 2 3 2 6 2 8 3 1 3 4 3 7 4 NOTE SULLA MANUTENZIONE Controllare se l area di manutenzio...

Page 145: ...versi tipi di refrigerante non si contaminino tra loro Il serbatoio del refrigerante deve essere tenuto in posizione verticale durante il riempimento Attaccare l etichetta sul sistema con la quantit d...

Page 146: ...stallati saldamente e in modo cor retto In caso contrario si potrebbero verificare malfunzionamenti elettrici o danneggia mento delle parti L unit stata collegata ad una messa a terra sicura In caso c...

Page 147: ...unit funzioni in modalit raffreddamento Quindi chiudere completamente la valvola sul lato alta pressione valvola del liquido Dopo circa 30 40 secondi chiudere completamente la valvola sul lato di bass...

Page 148: ...icevano sollecitazioni esterne Cavi elettrici con capacit insufficiente collegamenti errati e terminali non sicuri possono causare scosse elettriche o incendi MANUALE PER L INSTALLATORE Riparazione di...

Page 149: ...ima del riutilizzo del refrigerante rigenerato essenziale che l energia elettrica sia disponibile prima di iniziare l attivit a Acquisire familiarit con l attrezzatura e il suo funzionamento b Isolare...

Page 150: ...numero corretto di bombole per mantenere la carica totale del sistema Tutte le bombole da utilizzare sono designate per il refrigerante recuperato ed etichettate per quel refrigerante cio bombole spe...

Page 151: ...sere rimossi assicurarsi che siano stati evacuati ad un livello accettabile per accertarsi che il refrigerante infiammabile non rimanga all interno del lubrificante Il processo di evacuazione deve ess...

Page 152: ...t This product must be send for environmental safe recycling Questo marchio indica che questo prodotto non deve essere smaltito con altri rifiuti domestici in tutta l UE Per prevenire possibili danni...

Page 153: ...efore the product has been marked with the symbol and the Declaration of Conformity has been issued and is available to the competent authorities regulating the market Certificato di Conformit CE TOYO...

Page 154: ...154...

Page 155: ...155 NOTES...

Page 156: ...413 74 50 38 http www toyotomi eu REPRESENTANTE OFICIAL ESPANA TOYOTOMI EUROPE SALES SPAIN S A CALLE TRIGO 9 BAJO 2 28914 LEGAN S MADRID Tel 34 91 6895583 Fax 34 91 6895584 http www toyotomi es This p...

Reviews: