OPERATION DETAILS
39˚C
15˚C
0rpm
Selected speed
Selected speed
Super low
20 sec.
Low
Temperature,
indoor heat
exchanger
Indoor fan
+3.0
+5.0
0
Hz
Frequency of
compressor
Designated
temperature
Room temperature
MAX
88Hz
MAX
88Hz
MIN 30Hz
MIN 30Hz
HEATING MODE OPERATION
•
The compressor will stop when operational frequency reached the minimum frequency and that condition has
been kept for
360 seconds and the room temperature becomes 5.0
°
C higher than it was set.
•
The compressor will re-start when room temperature becomes 3.0
°
C higher than it was set.
•
The operational frequency will be set every 120 seconds of operation.
The operational frequency setting will be calculated based on the deviation of the room temperature and the
set temperature on one end and the deviation factor at the time of previous setting on another.