2
Model:
Laser 531 / Laser 532
Heater Efficiency:
92.4%
Heat Rating:
High - 22,000 BTU/h
Med - 15,000 BTU/h
Low - 8,000 BTU/h
Fuel Consumption:
High - 0.165 gal/h (0.625 L/h)
Med - 0.113 gal/h (0.428 L/h)
Low - 0.060 gal/h (0.227 L/h)
Fuel system:
External tank (2)
Fuel Type:
1-K kerosene (ASTM D3699)
Low Sulfur No.1 Fuel (ASTM D396 S500)
Ultra Low Sulfur Diesel Fuel (ULSD) or
Ultra Low Sulfur Heating Oil (ULSHO) (ASTM D975 S15)
Dimensions (W × H × D):
19-5/8” × 23-5/8” × 16-1/2” (496 × 600 × 418 mm)
Weight:
38 lbs. (17 kg) Empty
Vent Pipe Hole:
2-3/4” – 3” (7.0 – 7.5 cm) diameter
Maximum Length of Vent Pipe System:
10ft. (3 m), 3 bents or less
Electrical Rating:
120 Volts AC, 60 Hz
Preheat - 240W
Burning - 48W
Typical Room Size (3):
920 square feet ( 0˚F)
1150 square feet (20˚F)
Frequency band(s) in which the radio equipment operates:
2.400GHz to 2.4835GHz
Maximum radio-frequency power transmitted in the
20dBm
frequency band(s) in which the radio equipment operates:
Wireless LAN:
IEEE 802.11n/g/b
SECTION A:
SPECIFICATIONS
(1)
(2)
(3)
Heat and vaporized water are produced by the combustion process of this heater. This rating does not take
into account heat loss due to condensation of water vapor.
External tank to be purchased from local suppliers.
0˚F Heat Load
= 24 BTU/ft
2
/hr
20˚F Heat Load = 20 BTU/ft
2
/hr
Room size for which this heater is suitable will vary depending on outside temperature, house insulation,
window size, and other factors.
Flame Sensor
Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order to
prevent fuel overflow. Error code will be displayed on the Operation panel.
Fuel Strainer
Special strainer catches dirt and impurities present in the fuel before it is sent to the burner.
Overheat Protector
Automatically stops all operations if the heater's inside cabinet reaches abnormally high temperature due to
motor malfunction or abnormal combustion, in order to prevent fire.
Power Failure Recovery System
If power fails during heater operation, heater will automatically reignite and maintain the normal selected
temperature, when power resumes.
Fully Vented System
Flue pipe system uses outside air for combustion and vents all combustion products to the outdoors.
1.
2.
3.
4.
5.
SAFETY FEATURES
Laser 531 / Laser 532 is equipped with the following safety features. Please familiarize yourself with these
features. When your heater is extinguished due to a safety mechanism, be sure to identify the problem
correctly.
Fuel pipe
Burner ring
Blower motor
Circulation fan
Heat exchanger
Heat shield plate
Burner
Peep hole
Flame sensor
Igniter
Red float release button
Fuel pump
Overheat protector
Drip tray
Fuel sump
Fuel strainer
Summary of Contents for Laser 531
Page 35: ......