BODY ELECTRICAL - AIR CONDITIONING
165BE23
Discharge
Port
Variable
Scroll
Discharge
Suction
Intake Port
Fixed Scroll
Compression
BE-53
Operation
1) Suction
As the capacity of the compression chamber, which is created between the variable scroll and the fixed
scroll, increases in accordance with the revolution of the variable scroll, refrigerant gas is drawn in from
the intake port.
2) Compression
From the state at which the suction process has been completed, as the revolution of the variable scroll
advances further, the capacity of the compression chamber decreases gradually. Consequently, the
refrigerant gas that has been drawn in becomes compressed gradually and is sent to the center of the fixed
scroll. The compression of the refrigerant gas is completed when the variable scroll completes
approximately 2 revolutions.
3) Discharge
When the compression of the refrigerant gas is completed and the refrigerant pressure becomes high, the
refrigerant gas discharges through the discharge port located in the center of the fixed scroll by pushing
the discharge valve.