The gas control system is located on the right hand side of the firebox behind an access panel and the decorative firebox panel (if
installed). The fireplace is operated via a wall control and a hand held remote control unit.
The wall control is connected to the fireplace by a 40 ft. communication cable supplied with the fireplace.
Electrical
Note: Installation must be performed by a qulaified
installer, service agency or gas supplier.
Installation
1. Place the fireplace in the desired location.
2. Remove the window from the fireplace.
3. Remove access panel from right hand side of the firebox (Figure 22).
Lintel knock outs
There are six knock outs on top of the lintel. These
knock outs should remain in place and not knocked
out during installation. The knock outs are for a future
optional “TV KIT” which will allow a television to be
mounted above the fireplace while having the heat
from the fireplace re-directed to a vent which will be
located above the TV.
This fireplace is designed to finish either
flush with the facing material or can be
installed with a 4 1/2 inch recess, See
“Figure 12: TCWS54D Reccessed installation
details.” on page 10.
The fireplace can accommodate facing
material thickness from 1/2 of an inch to 2
1/4 inches if installing flush.
Care should be taken to correctly determine
the facing material thickness so that the
fireplace is positioned so that the front of the
fireplace is flush with the facing material.
Facing material must not interfere with the
ability for the door or the screen to open.
Fireplace Facing Allowance
Figure 20: Knock outs for future TV Kit feature.
NON-COMBUSTIBLE
FINISH MATERIAL
NON-COMBUSTIBLE
BUILDING MATERIAL MAY NOT
EXTEND PAST THIS POINT
SCREEN
DOOR
Figure 21: Facing edge location.