WARNING
This conversion kit
shall be installed by a
qualifi ed service agency
in accordance with the
manufacturer's instructions
and all applicable codes
and requirements of
the authority having
jurisdiction.
If the information in these
instructions is not followed
exactly, a fi re, explosion
or production of carbon
monoxide may result
causing property damage,
personal injury or loss of
life.
The qualifi ed service
agency is responsible for
the proper installation of
this kit.
The installation is not
proper and complete
until the operation of the
converted appliance is
checked as specifi ed in the
manufacturer's instructions
supplied with the kit.
If the unit is to be used on propane convert as follows using the components
supplied with this burner:
CAUTION
The gas supply and electrical power shall be shut off before proceeding with
the conversion.
Note:
Factory supplied components must be
used to ensure correct input.
After conversion confi rm proper manifold
pressure.
1. If installed remove the rocks from the
burners.
2. Remove the burner from the burner
tray by gently lift up the left side of the
burner and disengage the burner tube
from the orifi ce. (Fig. #14)
3. Using a 1/2” wrench, undo the
natural gas burner orifi ce,
(marked
#32
). Apply a small amount
of pipe joint compound to the threads
of the propane burner orifi ce
(marked
1.8mm
) to ensure a good
seal, before screwing it into the fi tting.
Loosen the primary air shutter screw,
open shutter to give a gap of 13/64”
and re-tighten. Repeat on other
burner.
(Fig.
#15)
4.
With a 7/16” wrench loosen the pilot
head on the pilot assembly. (Fig. #16)
MINIMUM RATE SCREW
PART # 5005.016 SIZE 1.092mm
BURNER ORIFICES (2)
PART # 5022.85 SIZE 1.8mm
CONVERSION LABEL
PART # 5052.52083
Fig #15
Fig #16
Fig #14
Fig #13a
6
TCWS.54NG04.C 040907
Propane Conversion