Fig #25
12) Fill in the date and the name of the
person who performed the conversion
in the white area on the conversion
label. Peel off the protective backing and
apply the conversion label directly over
the gas specifi cations on the rating label.
13) Attach the access panel to the side of
the fi rebox with the previously removed
screws. (Fig. #25)
Note: Gasket must be installed with
access panel.
LP GAS/
DU GAZ LP
12.5 in/wc /12.5 po/c.e.
(3.11 kPa)
13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
11.0 in/wc / 11.0 po/c.e.
(.95 kPa)
3/32” (2.38 mm)
Max.: 61,000 (17.9)
Min.: 46,200 (13.5)
260411 6-TC42C 5052.5206C
Date: ______________________
By / Par: ___________________
Kit # TC42.LPKTB/EB/EC for use with model:
Pour utilise avec du modèle:
This appliance was converted
to PROPANE GAS with this
kit on this date by the or-
ganization which accepts the
responsibility that this conver-
sion has been properly made.
/ Cet appariel etair converter
au gaz LP par l’emploi de la
trousse de conversion par une
organization qui accepte la
responsibilité pour une instal-
lation en bon état.
TC42
Series C
14
TC42.NG03C 020511-20