background image

5056.426C8

6

TC42_NG02DN_100117-12

Gas plumbing and vent con-
nections should be completed 
before proceeding.

The logs are fragile, and should 
be handled with care. Unpack and 
inspect log set. There should be a 
total of seven logs. 

Position the logs as indicated by 
the following pictures. The three 
main logs have holes and / or pins. 
Engage each pin in the corre-
sponding holes. The four smaller 
logs do not have holes or pins. 
They rest in position. Locate as 
per the diagrams (Figures 11-18).

 Log Placement 

1

Figure 11:  First log placement.

2

Figure 12:  2nd log placement.

Summary of Contents for TC42.NG02DN

Page 1: ...for future reference TC42 COUNTRY HOME BURNER KIT INSTALLATION INSTRUCTIONS NATURAL GAS ONLY PART TC42 NG02DN For TC42 Series D Fireplaces These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kepttogether RefertotheInstallationandOperatingInstructionsfor proper gas supply safety requirements and operating instructions ...

Page 2: ...urner Installation 1 Place the keyhole slots in the burner Figure 2 over the two screws located in the firebox base Figure 3 2 Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws 3 Remove the valve control box access cover from side of firebox Figure 4 Figure 2 Attaching burner to floor of fireplace Bolts Figure 3 Bolts for burner Figure 4 Control ce...

Page 3: ...or wires Bulkhead plate Figure 6 Ignition and sensor wires routing 4 Attach the manifold and pilot supply tubes to the bulk head fitting and tighten Figure 5 Ensure that all connections are gas tight 5 Feed the ignition and sensor wires through the bulkhead plate Figure 6 to the inter face ...

Page 4: ...dule A panel set must now be installed See Installation and Operating Instructions manual for details 6 Attach the ignition and sensor wires to the module Figure 7 7 Reinstall the access panel to the valve control box 8 Position the slots of the grate securing brackets over the holes in the floor shield and secure with the two screws Figure 8 ...

Page 5: ...the pan at rear and gradually slope forward to the firebox floor at the front covering both burner tubes Figure 10 Place remaining ember material out side of the burner pan as desired to cover up gas lines and brackets Note Ember material placement and amount will affect flame appear ance More ember material results in lower flame height Add or remove as needed until desired flame affect Figure 9 ...

Page 6: ...ct log set There should be a total of seven logs Position the logs as indicated by the following pictures The three main logs have holes and or pins Engage each pin in the corre sponding holes The four smaller logs do not have holes or pins They rest in position Locate as per the diagrams Figures 11 18 Log Placement 1 Figure 11 First log placement 2 Figure 12 2nd log placement ...

Page 7: ...7 TC42_NG02DN_100117 12 5056 426C8 3 Figure 13 3rd log placement 4 Figure 14 4th log placement ...

Page 8: ...5056 426C8 8 TC42_NG02DN_100117 12 5 Figure 15 5th log placement 6 Figure 16 6th log placement ...

Page 9: ...e Improper placement of logs will cause sooting on internal parts and glass The logs may need to be repositioned slightly to avoid excessive flame impingement 7 Figure 17 7th log placement 3 5 7 4 2 6 1 Figure 18 Completed log set placement ...

Page 10: ...ution Burner area may be hot Turn off the fireplace and allow the unit to cool before proceeding Caution Proper air shutter setting is a must The flame should be just orange and lazy It should NEVER be set so that it cre ates sooting on internal parts and glass Burner Flame Adjustment To Adjust See Figure 20 1 Open and remove window frame and set aside See Window Frame Removal sec tion found in th...

Page 11: ...EM DESCRIPTION PART NO ITEM DESCRIPTION PART NO 1 BURNER ASSEMBLY 1a GRATE 1b BURNER TRAY 1c BURNER TRAY SUPPORT SHIELD 1d BURNER TRAY SHIELD GASKET 1e MANIFOLD 1f 1 2 PIPE TO 1 2 TUBE CONNECTION 1g PILOT BRACKET 1h AIR DEFLECTOR Not shown 2 NOT SHOWN 3 ORIFICE NATURAL GAS 4 09mm 4 PILOT ASSEMBLY CONVERTIBLE 5 MAIN SUPPLY TUBE 6 PILOT TUBE 1 6 5 4 3 1a 1g 1f 1e 1d 1c 1h Kit Contents 11 TC42_NG02DN...

Page 12: ...ucts LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 ...

Reviews: