TC36.NGST03C 031111-20
16
Note: To test the gas pressure, turn off the gas
supply before removing the blanking plug from the
pressure test port. Verify gas pressures with the
fi replace lit and on the highest setting.
1)
Remove the blanking plug from the pressure test
port. The plug is located between the right side
lintel and fi rebox side. (Fig. #29)
CORRECT GAS PRESSURE REQUIREMENT:
Supply Pressure
Natural Gas
Propane
(For purpose of input adjustment)
Minimum
5.0” wc
12.5” wc
Maximum
13.9” wc
13.9” wc
Manifold pressure
Maximum
3.8” wc
11.0” wc
Minimum
2.1” wc
5.5” wc
2)
Thread the extension test fi tting into the open port.
(Fig. #30)
3)
Attach a pressure gauge onto the fi tting.
4)
When testing is complete shut of the gas, remove
the fi tting and replace the plug. Thread sealant will
be required to ensure a gas tight connection.
Gas Pressure Check
12) Fill in the date and the name of the
person who performed the conversion
in the white area on the conversion
label. Peel off the protective backing and
apply the conversion label directly over
the gas specifi cations on the rating label.
13) Attach the access panel to the side of
the fi rebox with the previously removed
screws.
Note: Gasket must be installed with
access panel.
LP GAS/
DU GAZ LP
12.5 in/wc /12.5 po/c.e.
(3.11 kPa)
13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
11.0 in/wc / 11.0 po/c.e.
(.95 kPa)
3/32” (2.38 mm)
Max.: 61,000 (17.9)
Min.: 46,200 (13.5)
260911 6-TC42C 5052.5206C
Date: ______________________
By / Par: ___________________
Kit # TC42.LPKTB/EB/EC for use with model:
Pour utilise avec du modèle:
This appliance was converted
to PROPANE GAS with this
kit on this date by the or-
ganization which accepts the
responsibility that this conver-
sion has been properly made.
/ Cet appariel etair converter
au gaz LP par l’emploi de la
trousse de conversion par une
organization qui accepte la
responsibilité pour une instal-
lation en bon état.
TC36.NGST03,04
TC42 Series C
ADD NAME
ADD DATE
Fig #29
Fig #30