Baffle Adjustment
Figure 29: Adjustable baffle ports.
The air baffle (Figure 29) is set to fully open before it is shipped and might need adjustment.
However, if adjustment is required, the sliding plates can be moved by inserting a screwdriver or
other object up through the baffle cover (Figure 30). There is a bracket on either end of the baffle to
use for easy adjustment. If the flame pattern is too hectic, close the baffle opening a half inch at a
time and monitor the flame with all glass panes installed.
NOTE: The more you close the baffle, the more the outer glass temperature will rise, as less heat is
being evacuated from the combustion zone.
The baffle cover is secured with six bolts (Figure 30). If removal of the baffle cover is necessary,
always remove the two center bolts last, as well as installing them first when re-installing the baffle
cover.
Figure 30: Adjustment accessible through the baffle
cover.
32
031220-60
Architectural Series
100004782