background image

For technical support, please contact your retailer.

www.townandcountryfireplaces.net

2975 Allenby Rd., Duncan, BC V9L 6V8

Printed in Canada

© 2019 Copyright Pacific Energy Fireplace Products LTD 

Reproduction, adaptation, or translation  
without prior written permission is prohibited, 
except as allowed under the copyright laws. 
 

Summary of Contents for 22150036

Page 1: ...this manual for future reference These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kepttogether RefertotheInstallationandOperatingInstructionsfor proper gas supply safety requirements and operating instructions TC42 CHALET BURNER KIT INSTALLATION INSTRUCTIONS PART 22150036 For TC42 Series D Fireplaces ...

Page 2: ... in the firebox base Figure 3 2 Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws 3 Remove access cover from side of firebox Figure 4 If this fireplace is to be used on Propane please convert prior to installation See pages 9 11 Figure 1 Package contents Figure 2 Attaching burner to floor of fireplace Bolts Figure 3 Bolts for burner Figure 4 Contro...

Page 3: ...pply tubes to the bulk head fitting and tighten Figure 5 Ensure that all connections are gas tight 5 Feed the ignition and sensor wires through the bulkhead plate Figure 6 to the interface Figure 5 Gas and pilot supply tubes Ignition and sensor wires Bulkhead plate Figure 6 Ignition and sensor wires routing ...

Page 4: ... 8 Position the slots of the grate securing brackets over the holes in the floor shield and secure with the two screws Figure 8 Ignition wire red Flame sensor wire white Interface module Figure 7 Interface module Figure 8 Securing the grate Apanelsetmustnowbeinstalled See Installation and Operating Instructions manual for details ...

Page 5: ...burner tubes 3 Place remaining ember material outside of the burner pan as desired to cover up gas lines and brackets Gas plumbing and vent connections should be completed before proceeding The logs are fragile and should be handled with care Unpack and inspect log set There should be a total of 7 logs Position the logs as indicated by the following pictures Place the rear log back against the tab...

Page 6: ...6 Log 2 Figure 11 Log 2 placement Log 3 Figure 12 Log 3 placement Place log 2 as pictured engaging the pins with corresponding holes on the underside of the log Install log 3 into the grate and pull it forward into position as shown ...

Page 7: ...7 TC42_NG06D_050919 16 100000385 Log 4 Figure 13 Log 4 placement Log 5 Figure 14 Log 5 placement Place the four remaining small logs on the floor of the firebox in the positions and order as shown ...

Page 8: ...100000385 8 TC42_NG06D_050919 16 Note Improper placement of logs will cause sooting on internal parts and glass Log 6 Figure 15 Log 6 placement Log 7 Figure 16 Log 7 placement ...

Page 9: ...n these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supp...

Page 10: ...emoving orifice Figure 20 Orifice Figure 21 Loosening the pilot head 7 Reinstall the manifold assembly 8 With a 7 16 wrench loosen the pilot head on the pilot assembly by a half turn Figure 21 9 Slide the pilot adjustment band over and ensure that the hole in the orifice band is showing Figure 22 shows the pilot band in natural gas position Figure 23 shows the pilot band in propane position ...

Page 11: ...o inside of control box where it will not be affected by the heat of the firebox Pilot adjustment band Figure 22 Pilot band in natural gas position Hole in sliding band indicates propane gas configuration Figure 23 Pilot band in propane gas position Cet appareil a été converti en gaz propane Numéro d assemblage j m a Firme Adresse l entreprise désignée ci dessus accepte la responsabilité que cette...

Page 12: ...me should be just orange and lazy It should NEVER be set to create sooting on internal parts and glass Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before proceeding Burner Flame Adjustment To Adjust 1 Open and remove window frame and set aside See Window Frame Removal section found in the Installation and Operating Instructions manual 2 Remove the log set and s...

Page 13: ...PROPANE CONVERSION KIT 22180008 ITEM DESCRIPTION PART NO 2a 2b 2c 2d 2g 2e 2f 2 6 1 3 5 4 1a 1b 1e 1d 1h 1c 1f 1g 1 BURNER ASSEMBLY 1a GRATE 1b BURNER INSULATION 1c BURNER TRAY SUPPORT SHIELD 1d PILOT SHIELD 1e TC42 NG01 BURNER WELD 1f MANIFOLD 1g 1 2 PIPE TO 1 2 TUBE CONNECTION 1h PILOT BRACKET 2 7 PCS LOG SET EMBER MATERIAL Not shown 2a LOG 1 2b LOG 2 2c LOG 3 2d LOG 4 2e LOG 5 2f LOG 6 2g LOG 7...

Page 14: ...100000385 14 TC42_NG06D_050919 16 ...

Page 15: ...15 TC42_NG06D_050919 16 100000385 ...

Page 16: ...nandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada 2019 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws ...

Reviews: