TOVIS P/N
MTG-1972XN
DATE
2002.03.11
REV NO.
0
TOVIS
Color Monitor Service Manual
PAGE
5/30
3. TECHNICAL FEATURES.
3-1. U-com(MCU) control with OSD.
U-com recognizes the computer signal and the signal output from control
board connected with wire. So the circuit is simplified.
3-2. Universal AC input voltage.
Power supply operates on AC100
∼
240volt 60/50Hz for use all over the world.
3-3. Protection Circuit for over-current.
When over-current happens in the circuit, the protection circuit operates in
order to prevent the components from electrical shock or other risks.
3-4. Override function
Is designed for the normal display when the monitor is powered on without
connection from the source (No signal message).
3-5. Control panel
If you are not satisfied with the factory mode size, position, color settings, use
the control panel to program those you prefer in each resolution mode.
Then, these adjusted settings are kept in memory even if you change
resolution mode or turn off the monitor.
3-6. I
2
C BUS control
It is designed by I
2
C BUS control for simplifying the circuit. The number of
total components is less than 610 pcs.
TOVIS CO., LTD.