- 14 -
tousek
/ EN_ST-63_02 / 25. 03. 2020
main layer
sub layer
settings/adjustments
light/ lamps
page 23
prewarning OPEN
OFF, 1...30s
= OFF
prewarning CLOSE
OFF, 1...30s
= OFF
court yard light
1
OFF, 5...950
= OFF
10s afterglow
green phase
5...120s
[ increment 1 ]
= 20s
clearance time
1...60s
[ increment 1 ]
= 5s
traffic light gate CLOSED
red light OFF
permanent RED
traffic light logic
green on both sides
green on one side
peripherals
page 24
traffic light
not active
active
locking
electric lock/magnetic clamp
drop bolt
reverse stroke
Reverse stroke only with activated locking!
with E-lock/magnetic clamp:
with drop bolt:
not active
0,5...8s
not active
active
delay magnetic clamp
OFF
0,1...1s
/
electric lock
not active
1...10s
/
drop bolt
/
OPEN and CLOSE
OPEN only
CLOSE only
additional module
gate status display 1
gate status display 2
diagnosis
page 28
status display
state display of all inputs
delete positions
NO
YES
factory settings
NO
YES
software version
show software version
serial number
show serial number
protocol
show protocol notes
menu item showed:
with traffic mode,
without traffic mode
swing / folding gate control ST63
+
–
ESC
ENTER
Note: Some changes in the functionality or operating logic are not accepted until the gate is
closed and the word „Ready“ appears on the display
.
Menu structure
Adjustments - overview
Note: deactivate locking
(Electric lock or drop bolt)
To deactivate locking, the menu item „locking“ has to be set to „Electric lock/magnetic clamp“ and the menu item „Electric
lock“ to „not active“ afterwards.