Important warning and safety notes for installation and operation

•   These installation- and operating instructions form an integral part of this product. They have been specifically written for professional installers trained and 

skilled in the trade and should be carefully read in their full length before carrying out the installation. It concerns the control only, not of the overall device 

“automatic gate”. After the installation this manual has to be handed over to the user.

•   Installation, connection, adjustments, putting into operation, and servicing may only be carried out by trained professionals in full accordance with these 

installation- and operating instructions.

•   The EU Machine Directive, laws and rules concerning the prevention of accidents, and laws and standards which are in force in the EU and in the individual 

countries have to be strictly followed.

•   The TOUSEK Ges.m.b.H. cannot be held liable for any claims resulting from disregards of the laws and standards in force during the installation and 

operation.

•   The product may only be used in accordance with its original purpose, for which it has been exclusively designed, and which is described in these installation 

and operating instructions.  The TOUSEK Ges.m.b.H. rejects any liability if the product is used in any way not fully conforming to its original purpose as 

stated herein.

•   The product is not suitable for installation in explosion-hazardous areas. The existance of inflammable gas and steam is of great danger !
•   The packaging materials (cardboard, plastic, EPS foam parts and filling material...) have to be properly disposed of in accordance with the applying recy-

cling- and environmental procection laws. They may be hazardous to children and therefore have to be stored out of children´s reach.

•   Before beginning with the installation the installer has to make sure that all mechanical components of the gate facility, like carrier profile/rail, gate frame and 

panels, guiding elements etc. are sufficiently supportive and resistant for the purpose of gate automation. Check also whether  the product has transport 

damages.

•   All electrical installations have to be made in full conformity with the applying rules and laws (e.g. using a fault current circuit breaker, proper grounding...).
•   An all-pole disconnecting main switch with a contact opening-gap of minimum 3 mm has to be foreseen.
•   When installing the safety device (photocells, safety edges, emergency-stops etc.) please comply with the valid direcitves/standards, the criteria of practical 

rules of conduct, the installation environment, the operating logic of the system and the effected force of the motorised gate.

•   The safety devices must secure possible bruise, shear and general danger areas of the motorised gate.
•   After installation the proper function of the gate facility and the safety devices has to be checked.
•   Place warning signs and notes of the valid regulations to indicate danger areas
•   With each installation the identification data of the motorised gate has to be placed in a visible place.
•   The electric motor heats up during operation. Therefore the device should only be touched after it has cooled off.
•   Children have to be instructed, that the gate facility as well as the belonging parts may not be used improperly, e.g. for playing. Furthermore handheld 

transmitters have to be kept in safe places and other impulse emitters as buttons and switches have to be installed out of children‘s reach.

•   Only original spare- and replacement parts may be used for repair of the product.
•   The TOUSEK Ges.m.b.H. rejects any liability for claims resulting from usage of the product in combination with components or devices which do not fully 

conform to the applying safety laws and rules.

•   The installer has to inform the user about all aspects of the automatic operation of the complete gate facility, as well as about emergency operation. The 

installer further has to supply to the user all instructions relating to the safe operation of the gate facility. The installation and operating instructions also 

have to be handed over to the user. 

•   The user has to be informed that he has to turn off the main power switch in case of malfunction of the product and that he can use the facility again after 

repair and adjustment works have been completed.

•  Please notice that the warranty will not be applicable if the label with the engine number has been removed or 

damaged.

 Maintenance

•  Maintenance works have to be carried out according to our maintenance plan (page12).

This manual is the sole property of the TOUSEK Ges.m.b.H. and may not be made available to competitors. All rights reserved. No part of it may be reproduced without our prior 

written permission. We will not accept liability for any claims resulting from misprints or errors. This edition of the manual replaces all earlier publications of the same.

Summary of Contents for Pass 838

Page 1: ...Installation and operating manual Barrier PASS 838...

Page 2: ...ontact opening gap of minimum 3 mm has to be foreseen When installing the safety device photocells safety edges emergency stops etc please comply with the valid direcitves standards the criteria of pr...

Page 3: ...boom can be opened and closed manually after loosening the emergency release hand wheel Due to its particularly massive execution and the very short opening and closing times the Tousek PASS 838 barr...

Page 4: ...ng lever 3 chain 4 gearing lever 5 balancing spring 6 euro standard lock cylinder 7 earthing bolt 8 activator bolt for door switch 9 door safety switch 10 drive shaft 11 Limit bolt boom OPEN 12 Limit...

Page 5: ...he barrier where you wish to mount the boom The following mounting steps differ in accordance of whether you wish to mount the round or the flat barrier boom Important grease the drive shaft put some...

Page 6: ...40 and disc with drive shaft A close the opening of boom with plastic plug Attach the plastic covers onto the boom and drive shaft end Fixing the flat boom example as left barrier M housing backside e...

Page 7: ...with the boom Then bolt 4 x with discs the boom carrier M with the slide in module inside boom E Now connect the boom B with cylinder head bolt M10 x 40 and disc with drive shaft A close the opening...

Page 8: ...An all pole disconnecting mains switch with a contact opening gap of min 3 mm has to be foreseen The gate facility has to be secured according to the valid safety regulations IMPORTANT The control li...

Page 9: ...or The switching time and also the boom limit positions can be defined by bolting in or out the limit stop bolts Note Please note that when the limit stop bolts are being adjusted AO or AG the limit p...

Page 10: ...may be moved manually slowly not faster than with the operator Torestoreoperationofthemotorpulltheemergencyrelease clockwise again firmly Move the boom a little so that the lever gear snaps into the...

Page 11: ...laws during installation or operation of the gate facility Note concerning cable laying The electric cables have to be laid in insulating sleeves whicharesuitableforundergroundusage Theinsulating slee...

Page 12: ...with the grease press Check and adjust the end positions opened and closed Check the proper function of the emergency release Check the proper function of the housing lid safety switch Check the gear...

Page 13: ...om the ground level to a minimum of 100mm Thefoundationdepthfromgroundleveltoshould have a minimum of 800mm frost resistant The foundation always has to be adjusted to the structure of the ground It s...

Page 14: ...ons subject to change 280 250 280 290 180 180 255 290 30 135 3 950 1100 116 100 100 base plate barrier width boom length NOTE 838V ST 838 L3 ST80 838 L4 ST80 838 L6 ST80 max barrier width 3m 4 5m 6m b...

Page 15: ...do a una razonada solicitud dentro de un plazo razonable en forma electr nica Para la preparaci n de la documentaci n t cnica est autorizada TOUSEK Ges m b H A1230 Viena Zetschegasse 1 Austria La m qu...

Page 16: ...ka 67 Tel 48 32 738 53 65 Fax 48 32 738 53 66 info tousek pl Tousek s r o Czech Republic CZ 130 00 Praha 3 Jagellonsk 9 Tel 420 2 2209 0980 Fax 420 2 2209 0989 info tousek cz We reserve the right to c...