- 6 -
tousek
/ E_FOLD330_43300306 / 31. 07. 2019
Before inserting the telescopic arm please unlock the automation (emergeny release) and turn it (as far as it goes) in the
direction of the arrow. Turn the shaft back of about 5°. With the door closed push the telescopic arm onto the shaft of the motor
and secure it with the worm screw.
Make sure that the doors open and close completely.
If this procedure is not be possible due to an inside wall, you can also choose another mounting procedure (see below), where
the automation is mounted in the entrance width of the gate .
Turn back (5°)
Emergency release
Insert the emergency release key in the emergency unlocking
device (on the front of the automation) and turn it up to the end
in a counterclockwise direction.
The automation is now unlocked and can be moved manually.
To restore the working condition simply turn the key clockwise
up to the end.
Setting of the power
Using the two bypass screws on the front side of the operator
you can separately adjusted the opening and the closing force.
Closkwise rotation
> bigger force
Anticlockwise rotation > smaller force