10
CONNECTING SWITCHES & I/O
OUTPUTS
... These are open collector transistors which can drive a load connected to the
internal 12V
12V
12V
12V supply or an external supply of up to 12V
12V
12V
12V. When the output is ON
ON
ON
ON it can sink a
current of 100mA
100mA
100mA
100mA. This example shows a siren connected to the internal 12V
12V
12V
12V supply.
To use a mains powered siren, connect the alarm output to a suitable external relay. These
however, are integral on some makes of siren.
DIGITAL INPUTS
... These are opto-coupled inputs that can be linked to use either the
power INT
INT
INT
INT supply, or an external supply of up to 20V
20V
20V
20V. If an external supply is used LK5
LK5
LK5
LK5
must be moved to other position and the exV
+V
+V
+V connected to the EXT+VE
EXT+VE
EXT+VE
EXT+VE
connection. The external switch or device must be capable of sinking 5mA
5mA
5mA
5mA to operate the
input. All inputs can be set in the software to be active High or Low.
This example shows a door switch connected to the internal power supply. LK5
LK5
LK5
LK5 must be
fitted as shown for this configuration. If external power supply is to be used LK5
LK5
LK5
LK5 must be
moved to other location as shown in diagram above and exV
+V
+V
+V connected to
EXT+VE
EXT+VE
EXT+VE
EXT+VE and 0V
0V
0V
0V to 0V
0V
0V
0V.
AUX IN
… This allows for the connection of certain interfaces such as the PC
PC
PC
PC----EI00
EI00
EI00
EI00----XXX
XXX
XXX
XXX
device to integrate third party equipment with the door controller. Supply voltage is
selectable between 5V
5V
5V
5V and 12V
12V
12V
12V via the link.
+V
0V