ROUGH-IN DIMENSIONS
• Turn off water supply and if necessary remove the old urinal.
• Install or relocate the water supply pipe and drain pipe to the specified
rough-in dimension shown above.
• Install adequate support to mount the urinal.
• Install the wall hanger per rough-in specification.
• Apply sealant tape to the drain pipe threads and install the outlet flange
to the drain pipe.
• Install the gasket on the outlet flange.
• Carefully position the urinal on the wall hanger.
• Secure the urinal to outlet flange with screws and washers.
2-1/2" (61mm)
12-1/4"
(310mm)
17" (ADA)
(432mm)
24"
(610mm)
3/4"
(19mm)
Spud
Outlet
Finished
Wall
2"
(51mm)
I.P.
Inside
Threads
Gasket
4-1/4"
(108mm)
Outlet Detail
14"
(356mm)
C/L
3/4" (19mm) I.P.S. Supply for
flushometer Vavlve
21-1/4"
(540mm)
11-1/2"
(292mm)
10-3/8"
(264mm)
12-1/4"
(310mm)
4-3/4"
(121mm)
4-1/4"
(108mm)
19-1/4"
(490mm)
12-1/4" (ADA)
(311mm)
INSTALLATION PROCEDURE
• Install the flush valve per manufacturer’s instructions.
• Turn-on the water supply and flush urinal several times.
• Carefully check all connections for leaks.
Outlet Flange