![Toto TES1ADC-05 Installation Instructions Manual Download Page 10](http://html1.mh-extra.com/html/toto/tes1adc-05/tes1adc-05_installation-instructions-manual_1139661010.webp)
5
Connecting the tubes and cords (Connection to the Tank Side)
6
Anchor the tank
Liquid soap tubes (white)
cords
Leveling Bolts
Leveling Bolts
Anchor bracket
Screws
Screws
Anchor
bracket
Clamp
Coupling cap
Liquid soap
tube (white)
White label
White label
Red label
Red label
Green label
Green label
Pair
Pair
Pair
Insert the liquid soap tubes into each of the cou-
pling caps located on the side of the liquid soap
pump and secure them with the clamps.
Connect each of the liquid soap tubes and the
pair of cords with each of the cords on the tank
side that have the same color label as the labels
affixed to the pump. (Three sensor cord cores
and two air pump cord cores.)
Insert into the tube coupling
caps and secure with the
clamps.
(1)
(2)
Insert the four bolts into the bottom of the tank
hand tight.
These bolts will need to be adjusted to level the
tank.
Install the two screws after the tank has been
leveled.
NOTE: If installing on a concrete floor, be sure to
use inserts before installing the two screws.
(1)
(2)
Anchor the tank with the supplied brackets.