EN
GLIS
H
15
DETECTION RANGE
Another infrared sensor.
PRECAUTION
PRECAUTION
Control stop
Elbow
Wall flange
The detection range of the infrared sensor is set at the factory and does not need
further adjustment.
DO NOT place the infrared sensor
of one Flush Valve so that it is in
line with the sensor of another
Flush Valve sensor.
DO NOT place the infrared sensor in
front of a mirror, stainless steel wall,
or other highly reflective surface.
NOTE:
In some cases, the valve may not
detect a user if the toilet seat is left
in an upright position. This can be
due to the rough-in dimension or
gap of the open front commercial
seat. Please lower the seat or
arrange with a TOTO or other
plumbing contractor to change the
height of the valve.
The sensor can have trouble
detecting users wearing black
clothes in some conditions.
Infrared sensor of the automatic
Flush Valve.
Infrared sensor of the automatic
Flush Valve.
Mirror, stainless steel wall or other
highly reflective surface.
Use chrome plated
elbow to adjust the
height of TOTO
EcoPower Flush
Valve from the
fixture.
TET6LA, TET6UA
TET6GA
TET1GA, TET1LA, TET1UA
TEU1GA, TEU1LA
TEU1LA
33-1/2"
(850mm)
15°
Max 19-11/16”
(Max 500mm)
33-1/2"
(850mm)
20°
Max 21-1/4”
(Max 550mm)