TRWS indicator
user’s manual
SECTION 3 INSTALLATIONS
GENERAL INSTALLATION
The scales should be sited in a location that will not degrade the accuracy.
Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning
vents.
Avoid unsuitable tables. The tables or floor must be rigid and not vibrate. Do not place
near vibrating machinery.
Avoid unstable power sources. Do not use near large users of electricity such as
welding equipment or large motors.
Avoid high humidity that might cause condensation. Avoid direct contact with water.
Do not spray or immerse the scales in water.
Avoid air movement such as from fans or opening doors. Do not place near open
windows.
Keep the indicator clean.
Do not stack material on the scales when they are not in use.
INSTALLATION OF TRWS SERIES
Please make the load cell connector from the load cell follow the drawing below
Attach the AC power adapter to the connector on the back of the indicator.
If you use TRWS for a platform scale, you can use attached indicator bracket.
Load cell connect as below (5pin air connecter)
-3-
EXC+
SEN+
SEN-
EXC-
SIG+
SIG-
SHIELD
5
5
3
2
4
4
1
LOAD CELL