![Totalcomp TRWS Series Service Manual Download Page 21](http://html1.mh-extra.com/html/totalcomp/trws-series/trws-series_service-manual_1138964021.webp)
TRWS indicator
user’s manual
SECTION 12 TECHNICAL PARAMETERS
Press
UNIT
key and
PRINT/M+
key together when normal weighing mode, display
shows “
F0 H-L
”, press
TARE
key
until display shows “
PrOG
”, press
ZERO
key,
display shows “
PIN
”, press momentarily
G/N
、
then
UNIT
、
then
ZERO
key to enter
setting mode, press
TARE
key to select parameter, press
ZERO
key to enter into
Function and Sub-function, press
UNIT
key to escape.
FUNCTION SUB-FUNCTION DESCRIPTION
P1 REF
AZN 0
This option is used to select the auto zero range;
Options : 0.5d, 1d, 2d, 4d
0-AUTO
This option is used to select the auto zero range
when the indicator is turned on and off.
Options : 0%, 2%, 5%, 10%, 20%
0- RANGE
This option is used to select the manual zero
range when press the ZERO key.
Options: 2%, 4%, 10%, 20%, 50%, 100%
speed
Set ADC speed, press U. Wt. Key to select ADC
speed, press Tare key to enter
7.5: 7.5 times per second
15: 15 times per second
30: 30 times per second
60: 60 times per second
Note: 15 times per second or 30 times per
second are recommendatory
P 2 CAL
DECI
This option is used to select the decimal
Options : 0, 0.0, 0.00, 0.000
INC
This option is used to select the division
Options : 1, 2, 5, 10, 20, 50
CAP
This display will show xxxxxx for setting the
capacity.
CAL
linear
Calibrate, see detail in section 10.
nonlin
P3 P RO
TRI
This display will show xxxxxx for trimming the
load cells, see detail in service manual.
COUNT
This display will show xxxxxx for indicating the
internal counts.
gra
Set the gravity.
RESET
This display will show SURE for recovering the
factory default setting.
P4 CHK
Mode 1
This is mode of the natural scale
Mode 2
This is animal scale
Scale can lock reading when little unstable
MODE 3
This is a subtraction scale (PRINT out
“-“ weight)
MODE 4
Peak Hold mode. (Scale can hold maximum
reading)
-18-