TRWS indicator
user’s manual
FUNCTION MENU SETTINGS
FUNCTION SUB-FUNCTION
DESCRIPTION
DEFAULT
VALUE
F4 Prt
Set the RS-232 , at first set RS-232 working mode
(press
TARE
key to change, press
ZERO
key to enter)
P Prt
: print weighing ticket when the
PRINT/M+
key is
pressed,
P Cont
: send weighing data continuously, connect to
PC ,
ASK
: ask and answer mode (bi-direction mode), connect
to PC.
Command
“R”: send weighing data to PC
Command
“T”: do tare operate
Command
“Z”: do zero operate
P cnt2
: send weighing data continuously, connect to
PC, the other mode to send data.
P stab
: print after stable.
P auto
: auto print mode.
Seire
:
connect with remote display (also send
continuously)
Then set baud rate
After set working mode, display will show
b
xxx, this is
current baud rate, you select baud rate by
TAKE
key ad
press
ZERO
to enter.
If you set
p cont
, then need set communication
protocol, display will show
Con
x, con1 is standard
protocol, con2 and con3 is other communication
protocol, see detail in section 9.
If you set printer (
P PRT
,
P AUTO
), then you can set print
out format.
D
isplay show “
LAB
x”, set gross/acc print format, you
can see detail below.
These parameter only available in MODE0 (normal
mode), see detail in section 12.
set printer type,
TY-TP
: mini ticket printer
TY 711
: A711 label printer
LP-50
: LP-50 label printer
Then set
ACC
on/off.
Acc on
: set accumulation and print working at the same
time.
Acc off
:
set print without accumulation.
P Prt
Prog
Pin
Enter the programming and calibration menus
by entering the correct password. See the
section 12.
-11-